논문 상세보기

축전식 탈염공정을 이용한 하수중의 용존염 제거특성 연구 KCI 등재

The removal characteristics of dissolved solid in wastewater during a capacitive deionization process

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/327241
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
상하수도학회지 (Journal of the Korean Society of Water and Wastewater)
대한상하수도학회 (Korean Society Of Water And Wastewater)
초록

Capacitive deionization(CDI) has many advantages over other desalination technologies due to its low energy consumption, less environmental pollution and relative low fouling potential. The objectives of this study are evaluate the performance of CDI which can be used for dissolved salts removal from sewage. To identify ion selectivity of nitrate and phosphate in multi-ionic solutions and adsorption/desorption performance related to applied potential, a series of laboratory scale experiments were conducted using a CDI unit cell with activated carbon electrodes. The CDI process was able to achieve more than 75 % TDS and NO3-, NH4+ removals, while phosphate removal was 60.8 % and is inversely related in initial TDS and H3- concentration. In continuous operation, increasing the inner cell pressure and reduction of TDS removal ability were investigated which are caused by inorganic scaling and biofouling. However a relative mild cleaning solution(5 % of citric acid for calcium scaling and 500 mg/L of NaOCl for organic fouling) restored the electrochemical adsorption capacity of the CDI unit to its initial level.

저자
  • 신경숙((주)한화건설) | Kyong-Suk Shin (Hanwha Engineering & Construction) Corresponding author
  • 이태우((주)한화건설) | Tae-Woo Yi (Hanwha Engineering & Construction)
  • 차재환((주)한화건설) | Jae-Hwan Cha (Hanwha Engineering & Construction)
  • 임윤대((주)한화건설) | Yoon-Dae Lim (Hanwha Engineering & Construction)
  • 박승국((주)한화건설) | Seung-Kook Park (Hanwha Engineering & Construction)
  • 강경석((주)시온텍) | Kyoung-Suk Kang (Siontech Co. Ltd)
  • 송의열(대전광역시시설관리공단) | Eui-Yeol Song (Daejeon Metropolitan City Facilities Management Cooperation)