A study was carried out to establish a detection method for irradiated black and white pepper. Samples were packed in polyethylene bags and irradiated with 2.5, 5, 7.5, 10 and 15 kGy using a Co-60 irradiator. The samples were suspended in water, and alkalized with sodium hydroxide solution. Apparent viscosity was determined after heat gelatinization using a Brookfield DV-III rotation viscometer at 30 with 30, 60, 90, 120, 150, 180, and 210 rpm. Means and standard deviations of the viscosities of all samples decreased by increasing the stirring speeds. The viscosities increased in all samples by increasing the concentration. Regression expressions and coefficients of viscosity which decreased with increasing irradiation dose of 10% and 13% black pepper, and 7% and 10% white pepper were 0.9531 (y=-131.29x+1,769.0), 0.9725 (y=-351.33x+4,036.0), 0.9731 (y=2,208.0e^(-0.3546x)), and 0.9959 (y=5,116.0e^(0.2887x)), respectively, at 120 rpm. This trend was similar for all stirring speeds. These results suggest that the detection of irradiated black and white pepper at various doses is possible by the viscometric method.