논문 상세보기

하수처리장 방류수에서 TOC와 COD 유기물관리 KCI 등재

Management of TOC and COD Organic Matter of Effluents in Sewage Treatment Plants

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/346087
서비스가 종료되어 열람이 제한될 수 있습니다.
한국환경과학회지 (Journal of Environmental Science International)
한국환경과학회 (The Korean Environmental Sciences Society)
초록

In this study, the organic matter of effluents from sewage treatment plants, located in the Nakdong watershed was investigated. Regression equations were computed using treated sewage data to convert the chemical oxygen demand(COD) concentrations, which are mostly available from an open database, into total organic carbon(TOC) concentrations. The average concentration of organic matter in the sewage treatment plant effluents were 2.2 16.8 mg/L for COD and 3.4 14.3 mg/L for TOC. The concentrations of COD were positively correlated with the TOC concentrations. The correlation between COD and TOC was relatively high, at 0.865(p<0.01). Based on these results, regression analysis was conducted. The regression equation for TOC was 1.651×CODMn-0.084 (R2=0.84). Furthermore, organic matter-related databases for more sewage treatment plants need to be built in order to establish TOC standards and manage the water quality.

목차
Abstract
 1. 서 론
 2. 재료 및 방법
  2.1. 조사대상지의 개요
  2.2. 조사방법
 3. 결과 및 고찰
  3.1. CODMn와 TOC의 정도관리
  3.2. 하수처리장별 분석결과
  3.3. 하수처리장 방류수의 유기물 항목별 상관관계
 4. 결 론
 REFERENCES
저자
  • 황석호(금오공과대학교 환경공학과) | Seuk-Ho Hwang (Department of Environment Engineering, Kumoh national Institute of Technology)
  • 박제철(금오공과대학교 환경공학과) | Je-Chul Park (Department of Environment Engineering, Kumoh national Institute of Technology) Corresponding author