초록

The purpose of this paper is to assess the effect of surface characteristic of GFRP rebar on concrete-reinforcement bond behavior. For sample preparation, 10 GFRP rebar with two types of surface conditions were used to fabricate 15×15×15cm sized GFRP reinforced concrete. Then, pull-out test was carried out on each concrete samples until the maximum bond strength was achieved. From the test result, it was found that the maximum bond strength at the lattice type is 1.38 times higher than that for unidirectional surface.