논문 상세보기

Analysis of Power Generation Efficiency and GHG Reduction Effect by Application of Low Temperature Catalyst and High Efficiency Dry Flue Gas Treatment System

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/352337
서비스가 종료되어 열람이 제한될 수 있습니다.
한국폐기물자원순환학회 (Korea Society Of Waste Management)
초록

To achieve energy efficiency improvement is used to lower temperature for emission gas at catalyst inlet, or to reduce/stop using steam to reheat emission gas. Saved energy from this process can be used as power source in order to increase generation efficiency. Dry emission gas treatment, on the other hand, is the technology to increase generation efficiency by using highly efficient desalination materials including highly-responsive slaked lime and sodium type chemicals in order to comply with air pollution standards and reduce used steam volume for reheating emission gas. If dry emission gas is available, reheating is possible only with the temperature of 45℃ in order to expect generation efficiency by reducing steam volume for reheating. Retention energy of emission gas from combustion is calculated by emission gas multiplied by specific heat and temperature. In order to obtain more heat recovery from combustion emission gas, it is necessary to reduce not only exothermic loss from boiler facilities but emission calorie of emission gas coming out of boiler facilities. In order to reduce emission calorie of emission gas, it is efficient to realize temperature lowering for the emission gas temperature from the exit of heat recovery facility and reduce emission gas volume. When applying low temperature catalysts, the energy saving features from 0.03% to 2.52% (average 1.28%). When increasing the excess air ratio to 2.0, generation efficiency decreases by 0.41%. When the inlet temperature of the catalyst bed was changed from 210℃ to 180℃, greenhouse gas reduction results were 47.4, 94.8, 118.5, 142.2 thousand tons-CO2/y, CH4 was calculated to be 550.0, 1100.1, 1375.1, 1650.1 kg-CH4/y, and N2O was 275.0, 550.0, 687.6, 825.1 kg-N2O/y. In the case of high efficiency dry flue gas treatment, reduction of greenhouse gases by the change of temperature 120~160℃ and exhaust gas 5,000 ~ 6,500 ㎥/ton is possible with a minimum of 355,461 ton/y of CO2 and minimum 4,125 tons of CH4/y to a maximum of 6,325 ton/y and N2O to a minimum of 2,045 kg/y to a maximum of 3,135 kg/y.

저자
  • Y. S. Yoon(Waste-to-Energy Research Division, Environmental Resources Research Department, NIER)
  • J. S. Bae(Waste-to-Energy Research Division, Environmental Resources Research Department, NIER)
  • E. H. Kwon(Waste-to-Energy Research Division, Environmental Resources Research Department, NIER)
  • H. Y. Park(Waste-to-Energy Research Division, Environmental Resources Research Department, NIER)
  • T. W. Jeon(Waste-to-Energy Research Division, Environmental Resources Research Department, NIER)
  • Y. K. Lee(Waste-to-Energy Research Division, Environmental Resources Research Department, NIER)