This study reduced and built Street Canyons created by skyscrapers in order to verify effect of Street Canyons by green wall within the city centre and analysed influence factors on temperature reduction according to applicative types of green wall in the lab. Applicative types were divided into three types such as non- greening type(Case A), one-side greening type(Case B), both side greening type(Case C). The result of analysis of each types showed that average temperature of Case B and Case C is respectively 1.0℃ and 1.7℃ lower than Case A. The result of analysis of WBGT was that the highest temperature was given by Case A(40.2℃) and second one was from Case B(39.8℃) and third one was from (39.1℃) and in UTCI Case A records the highest temperature of 34.7℃ and Case B provided the second highest temperature of 33.9℃ and Case B gave the lowest temperature of 32.7℃. In PMV the highest temperature of 2.65 was from Case B and second one of 2.61 was from Case A and third one of 2.54 was from Case C. Duncan analysis of each types based on solar radiation and thermal comfort generated that there was analytical significance between Case A and Case B and Case B in terms of each types of average temperature reduction. The significance of thermal comfort in WBGT, MRT, PMV showed non-significance but, In UTCI it was analysed that there was significance between Case C and Case A.