논문 상세보기

전기비저항 측정을 이용한 양생온도에 따른 고유동 콘크리트 응결 영향 평가

Setting time evaluation of self-consolidating mortar under various curing temperature

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/356752
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

Recently, high-performance and high-fluidity concrete have been studied and developed because high-rised build is constructed. An early-age properties of these concretes have been studied and developed bacause of comparing existed concrete. This study proposed non-destructive method as electrical resistivity measurement, which evaluates setting time of cement-based materials. An assessment of the effect on the setting time was studied on the addition of a superplasticizer to delay the setting time and the curing temperature to promote the setting time. 6th of samples prepared mortar according to adding superplasticizer(PNS) or curing temperature and measured the electrical resistivity during 24 h. As the results, mortars which curing higher temperature were promoted rising time which is setting time in the electrical resistivity, also mortars which adding superplasticizer were retard rising time.

목차
Abstract
 1. 서 론
 2. 샘플 제작 및 시험 방법
 3. 해석결과 및 고찰
 4. 결 론
 참고문헌
저자
  • 이한주(경북대학교 건설방재공학과) | Hanju Lee
  • 임홍재(경북대학교 건설방재공학과) | Hong Jae Yim 교신저자