This study is a basic study to CGS, which originates from the IGCC, as fine aggregate for concrete. The study measured density, water absorption ratio, solid volume percentage for grain shape, fineness modulus, grading curve of physical properties of fine aggregate. As a result, the density and solid volume percentage for grain sheet were found to be satisfactory in the aggregate for content (KS F 2527).Water evaluation ratio, fitness modulus, and grinding curve did not meet KS standards. Therefore, it is deemed necessary to adjust the grain size through sieving in case of fineness modulus and grinding curve.