W/C와 골재 크기에 따른 프리플레이스트 콘크리트 감쇠 특성

Damping Properties of Preplaced Concrete According to W/C and Aggregate Size

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/367657
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

This study investigated the damping properties of preplaced concrete with W/C and coarse aggregate size was . Experimental results show that the damping ratio of the C40 is 2.63%, which is 1.72 times higher than the damping ratio of the C30 of 1.53%. The higher the water cement ratio, the higher the damping ratio is. In addition, the damping ratio of the C-PA series is reduced by 17% to 60% as compared with the C-series. The difference of the damping ratio due to the coarse aggregate size in the C-PA series was found to be within the standard deviation

저자
  • 박세언(전남대학교 건축공학과) | Park Se Eon
  • 최정일(전남대학교 건축공학과) | Choi Jeong-Il
  • 이방연(전남대학교 건축학부) | Lee Bang-Yeon 교신저자