논문 상세보기

균열보수 주입재 적용에 따른 BFRP-콘크리트 계면의 인발 부착강도 성능 평가

Evaluation of Pull-out Strength of BFRP-Concrete Interface with Concrete Crack Repair

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/367759
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

In this study, an experimental evaluation was made on the change of the pull - out performance of BFRP concrete interface after repairing cracks on the lower surface of reinforced concrete by using basalt fiber which is environment friendly and heat - resistant compared to glass fiber. The test standard was ASTM D7522 / D7522M, and the influence factor was considered as the crack thickness. Test results showed that the fracture pattern was the same regardless of the crack thickness and the bond stress was measured similarly.

저자
  • 정우영(강릉원주대학교 토목공학과) | Jung Woo Young
  • 김가람(강릉원주대학교 토목공학과) | Kim Ga Ram
  • 조돈우(강릉원주대학교 토목공학과) | Cho Don Woo