In the water supply pipeline system polyethylene (PE), polyvinyl chloride (PVC), and ductile cast iron pipe are mostly used. However, they have some problems such as reduced durability due to material degradation, defects in connections, the pipelines breakage, and lack of continuous maintenance. Recently, research on durable and outstanding corrosion resistance glass fiber reinforced polymer plastic (GFRP) pipe is being actively conducted. GFRP is classified into the flexible pipe and when soil pressure and live load act on buried GFRP pipe, the load acting on the pipe is transferred to the surrounding soil. So, pipe will support the load with the surrounding soil. In this paper, to apply GFRP pipe for the water supply pipeline system, the structural reliability of GFRP water supply pipe buried underground should be investigated by examining the mechanical properties of GFRP pipe as well as the soundness of the pipe under buried state. The field test of buried pipe is conducted and the results are analyzed and discussed.