In this study, numerical simulation has been conducted to investigate flow characteristics in air supply room for container vessels by a 3-dimension numerical simulation. A commercial CFD program, FLUENT, is used on the analysis. It is shown that the air supply efficiency in this room can be improved by changing position of axial fan, even though other conditions still remain unchanged.