초록

PURPOSES : This study was conducted to analyze the problems of the permeable block by objectively evaluating the quality of the permeable block and providing basic data to improve the quality and construction defect of the permeable block pavement in accordance with the continuously increasing demand of the permeable block.
METHODS : In this study, we evaluated the current quality standard suitability of nine products to evaluate the current quality level of domestic production permeable blocks. The evaluation items were evaluated for surface layer thickness, block dimension, strength, and permeability coefficient, and the Korea Standard suitability for these evaluation items was analyzed. In addition, a three-dimensional finite element analysis was conducted to determine the effect of vehicle load on the deformation of block pavement structure.
RESULTS : The results demonstrated that the surface layer (colored layer) thicknesses of domestically produced permeable block products were different according to the quality standards, and the dimensions were evaluated to be excellent for domestic permeable blocks currently being produced and delivered. In addition, the strength and permeability coefficient evaluation result demonstrated that all products meet the strength and permeability coefficient quality standards, but the correlation between these strengths and permeability coefficients is not high. The quality standard of strength and permeability coefficients is evaluated as being sufficiently achieved by domestic production technology.
CONCLUSIONS: The intensity and permeability coefficients measured in this study were in line with the quality standards; however, the variable coefficient was found to have a significant difference in the quality control level from a maximum of 26% to a minimum 1.7%.

목차
ABSTRACT
 1. 서론
 2. 콘크리트 투수블록 품질기준 및 실험방법
  2.1. 국내 투수블록 품질기준
  2.2. 투수블록 품질적합성 평가방법
 3. 실내물성 평가결과
  3.1. 투수블록 외관조사 결과
  3.2. 투수블록 휨강도 및 투수계수
 4. 콘크리트 블록포장 3차원 유한요소 해석
  4.1. 유한요소모형
  4.2. 재료물성
  4.3. 하중조건
  4.4. 유한요소 해석 결과
 5. 결론