논문 상세보기

긴장 된 강선에서 주변 온도가 전기 임피던스에 미치는 영향

Influence of ambient temperature to electrical impedance on loaded steel wire

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/381293
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

This paper presents the results of the tests on electrical impedance for the steel wire under the effect of ambient temperature and stress level shift. The experiments are carried out in variable temperature conditions ranging from 30 to 60 ℃ and different stress levels ranging from 10% to 70% of yield strength. The results show the relationship between electrical impedance and temperature is a linear correlation at all stress levels.

저자
  • 응우옌 주이 훙(Department of Civil Engineering, Kyungnam University) | Nguyen Duy-Hung
  • 김병화(Department of Civil Engineering, Kyungnam University) | Kim Byeong Hwa