논문 상세보기

축산악취를 대상으로 직접관능법인 격자법과 Passive Air Sampler 측정 결과의 비교연구 KCI 등재

A comparative study on the sensory grid method and passive air sampler measurement results of livestock odor

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/382157
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
실내환경 및 냄새 학회지 (Journal of Odor and Indoor Environment)
한국냄새환경학회 (Korean Society Of Odor Research And Engineering)
초록

Since the implementation of the Odor Prevention Act in 2005, the number of odor complaints has continuously increased due to the increased interest in the living environment. The current odor control means is a concentrationbased method for the source of odor. That is why there is a difference between the odor sensitivity and the result of the odor measurement in the odor damage area. The government is considering the introduction of the grid method, which is the odor management method of Germany, as the method of odor investigation in the odor damage area in the second comprehensive Odor Prevention Policy (2019-2028). The grid method is receptor-based odor measurement method that investigators use to judge odors in the field, task that expensive and requires substantial manpower and time. To study an odor measurement method that is suitable for domestic conditions, this study compared the correlation between results based on the odor frequency concept grid method around the livestock facilities and the result of ammonia concentration measured by passive air sampler. The correlation coefficient (R) that is between the frequency of odor per spot for the entire odor and the ammonia concentration that was measured by passive air sampler was 0.65 which is relatively good. Among the entire odor detected by the grid method, the correlation coefficient (R) between the odor frequency selected only for livestock odor and the ammonia concentration was significantly increased to 0.80. In addition, the correlation between odor exposure (ECPexist) and the ammonia concentration for the overall odor was 0.81 (linear) and 0.86 (index). If only the livestock odors were selected, the correlation between odor exposure and the ammonia concentration was very high at 0.96 (linear) and 0.95 (index).

목차
Abstract
1. 서 론
2. 연구 방법
    2.1 연구대상시설 및 방법
    2.2 격자법
    2.3 Passive Air Sampler
3. 연구결과
    3.1 격자법을 이용한 축산악취특성 평가결과
    3.2 Passive Air sampler 측정결과
    3.3 격자법과 Passive Air sampler의 상관관계 분석
4. 결 론
References
저자
  • 오제범(한국환경공단 악취관리처) | Je-Beom Oh (Korea Environment Corporation Department of Odor Management) Corresponding author
  • 김형석(한국환경공단 악취관리처) | Hyung-Seok Kim (Korea Environment Corporation Department of Odor Management)
  • 김자영(한국환경공단 악취관리처) | Ja-young Kim (Korea Environment Corporation Department of Odor Management)
  • 김선태(대전대학교 환경공학과) | Sun-Tae Kim (Department of Environment Engineering, Daejeon University)
  • 홍성주(대전대학교 환경공학과) | Sung-Joo Hong (Department of Environment Engineering, Daejeon University)
  • 조강희(한국환경공단 기후대기본부) | Kang-Hee Jo (Korea Environment Corporation HQ of Climate & Air Quality Management)