논문 상세보기

경기도내 지하역사 실내공기질 특성 평가 KCI 등재

Evaluation on indoor air quality (IAQ) of subway station in Gyeonggi-do

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/408696
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
실내환경 및 냄새 학회지 (Journal of Odor and Indoor Environment)
한국냄새환경학회 (Korean Society Of Odor Research And Engineering)
초록

This study aimed to assess the pollution level in 13 crowded subway stations in an effort to understand the spatial and seasonal factors of Indoor Air Quality. The main measured items were particulate pollutants such as PM10 and PM2.5 and gaseous pollutants such as CO2, HCHO, Rn, TVOC, BTEX, and Styrene at concourses and platforms in the summer and winter periods. The influence of the draught created by the movement of the train was classified into lateral and island platforms, and the concentrations of PM by location (entrance, middle, and end) were statistically compared and analyzed. As a result, the concentrations of PM were confirmed high in the order of Platform > Concourse > Ambient air. In particular, in the case of platform PM10, the frequency exceeding the standard value (100 μg/m3) was 38.5% and the maximum concentration was 196.2 μg/m3. All gaseous pollutants were at lower levels than the standard, and the factors affecting CO2 and Rn were identified as the number of users and geological characteristics, respectively. The principal component analysis (PCA) demonstrated that PM was found to be a major indicator of the air quality management of subway stations. In particular, the concentrations at entrance and end areas in the lateral platform were about 1.4 times higher with regard to PM10 than in the middle area, and about 1.9 times higher with regard to PM2.5 due to the effect created by the draught produced by the movement of the train. Therefore, in order to manage PM in the platform area, a specialized management plan for places with particularly high PM concentration within the platform area is required. In addition, it is necessary to evaluate the effect created by the draught produced by train movement when selecting locations for measuring indoor air quality.

목차
Abstract
1. 서 론
2. 연구방법
    2.1 역사선정 및 연구기간
    2.2 측정항목 및 분석방법
    2.3 공간분포 분석
3. 결과 및 고찰
    3.1 역사내 오염물질 분포 특성
    3.2 실내공기질 영향인자에 대한 주성분분석(PCA)
    3.3 열차풍에 의한 승강장 미세먼지 공간분포 분석
4. 결 론
References
저자
  • 조진경(경기도보건환경연구원) | Jin-kyung Jo (Gyeonggi-do Institute of Health & Environment) Corresponding Author
  • 김동기(경기도보건환경연구원) | Dong-gi Kim (Gyeonggi-do Institute of Health & Environment)
  • 김세광(경기도보건환경연구원) | Se-kwang Kim (Gyeonggi-do Institute of Health & Environment)
  • 백민경(경기도보건환경연구원) | Min-kyung Baek (Gyeonggi-do Institute of Health & Environment)
  • 이수문(경기도보건환경연구원) | Soo-moon Lee (Gyeonggi-do Institute of Health & Environment)
  • 김태영(경기도보건환경연구원) | Tae-young Kim (Gyeonggi-do Institute of Health & Environment)
  • 최유경(경기도보건환경연구원) | Yu-kyung Choi (Gyeonggi-do Institute of Health & Environment)
  • 박종완(경기도보건환경연구원) | Jong-wan Park (Gyeonggi-do Institute of Health & Environment)
  • 김요용(경기도보건환경연구원) | Yo-yong Kim (Gyeonggi-do Institute of Health & Environment)
  • 오조교(경기도보건환경연구원) | Jo-gyo Oh (Gyeonggi-do Institute of Health & Environment)