논문 상세보기

선박기관실 조도개선과 에너지 절감에 관한 연구 KCI 등재

A Study on Illuminance Improvement and Energy Saving of Ship’s Engine Room

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/412728
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국기계기술학회지 (Journal of the Korean Society of Mechanical Technology)
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

In this study, the power consumption and illuminance were analyzed by replacing the fluorescent and incandescent lamps used as light sources for the engine room lighting of the training ship with LED light sources. By replacing 40W and 20W fluorescent lamps with 17W and 11W LED lamps, 40W fluorescent lamps reduced power consumption by 57.5% and 20W fluorescent lamps reduced power consumption by 45% and improved illumination by 56.8%. In particular, as a result of replacing 60W incandescent lamps with LEDs, power consumption was reduced by 85%. By installing an auxiliary cooling seawater pump that supplies cooling seawater to the engine control room air conditioner and boiler drain cooler in parallel, there is an energy saving effect of 88.1%. was confirmed.

저자
  • 김홍렬(목포해양대학교 실습선) | Hong-Ryeol Kim
  • 김부기(목포해양대학교) | Kim Bu Gi