In Spray Forming, specific enthalpy is a key parameter in the deposition process as it influences the thermal condition of the impinging droplets as well as that of the deposit surface. An empirical model for the distribution of specific enthalpy in the spray cone was developed as an easy to handle alternative to numerical models with which the descriptive partial differential equations are solved numerically. The model results were compared with the experimental data to validate its applicability.