In a recent preliminary inspection for disposal, the glass fiber waste (GFW), used as a pipe insulation, was judged as “pending evaluation” because some dust was found in drum opening tests. Therefore, additional inspection is required to ensure that the package corresponds with the acceptance criteria of the particulates. The dust was generated presumably due to GFW being used in a high-temperature environment for a long time, thus being easily degraded and crushed. For this reason, safety issues that may occur in the process of handling, transportation, and disposal are emerging. Therefore, in this study, a preliminary safety assessment of GFW disposal was performed, the exposure dose to the general public was derived, and compared with the dose limit. The evaluation was carried out in the following order: (1) evaluation of GFW radiation source term, (2) selection of accident scenario, (3) calculation of exposure dose, (4) comparison of evaluation results with dose limits, and confirmation of satisfaction. The average radioactivity of the GFW to be disposed of was used as the source term, and the main nuclides were identified as H-3, Fe-55, Co-60, Ni-63, and Pu-241. In general, the types of accidents that can occur at disposal facilities can be classified into falls, fires, collisions during transportation, off-site accidents, and nuclear criticality, and the accident scenarios are selected by analyzing and reviewing the probability of each accident. In this study, the accident analysis and scenarios presented in the safety assessment of the KORAD were reviewed, and the fire in the treatment facility, the fire in the storage facility, and the collision of the transport vehicle were selected as the evaluation scenarios. When an accident occurs, the radioactive material inside the container leaks out and diffuses into the atmosphere. In this evaluation, the internal and external exposure of the general public due to radioactive plume at the site boundary was evaluated and the dose conversion factors from ICRP-72 and FGR 12 were used. Based on the evaluation, general public was exposed to 0.004 mSv, 0.013 mSv, and 0.045 mSv, respectively, due to a fire at a treatment facility, at a storage facility, and in a transport vehicle. Most of the dose is due to internal exposure by Pu-241 nuclide, because the proportion of it in the waste is high, and when inhaled, the internal dose is high by emitting beta rays. It was confirmed that the result of dose was 0.4%, 1.3% and 4.5% of the annual dose limit, sufficiently satisfying the dose limit and safety.

저자
  • Woo Yong Kim(Korea Nuclear Engineering & Service, 65, Myeongdal-ro, Seocho-gu, Seoul) Corresponding author
  • Moon Oh Kim(Korea Nuclear Engineering & Service, 65, Myeongdal-ro, Seocho-gu, Seoul)
  • Seung Won Hwang(Korea Nuclear Engineering & Service, 65, Myeongdal-ro, Seocho-gu, Seoul)
  • Sang June Park(Korea Hydro & Nuclear Power Company Limited, 1655, Bulguk-ro, Munmudaewang-myeon, Gyeongju-si, Gyeongsangbuk-do)
  • Bang Suil(Korea Hydro & Nuclear Power Company Limited, 1655, Bulguk-ro, Munmudaewang-myeon, Gyeongju-si, Gyeongsangbuk-do)