논문 상세보기

Study on the Change in Neutron Absorbency Due to BSS Corrosion in the Accelerated Environment in the Spent Nuclear Fuel Pool

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/430798
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

In Korea, borated stainless steel (BSS) is used as a storage rack in spent fuel pools (SFP) to maintain the nuclear criticality of spent fuels. As the number of nuclear power plants and the corresponding amount of spent fuels increased, the density in SFP storage rack also increased. In this regard, maintaining subcriticality of spent nuclear fuels became an issue and BSS was selected as the structural material and neutron absorber for high density storage rack. Since it is difficult to replace the storage rack, corrosion resistance and neutron absorbency are required for long period. BSS is based on stainless steel 304 and is specified in the ASTM A887-89 standard depending on the boron concentration from 304B (0.20-0.29% B) to 304B7 (1.75-2.25% B). Due to the low solubility of boron in austenitic stainless steel, metallic borides such as (Fe, Cr) 2B are formed as a secondary phase. Metallic borides could cause Cr depletion near it, which could decrease the corrosion resistance of the material. In this paper, the long-term corrosion behavior of BSS and its oxide microstructures are investigated through accelerated corrosion experiment in simulated SFP conditions. Because the corrosion rate of austenitic stainless steel is known to be dependent on the Arrhenius equation, a function of temperature, the corrosion experiment is conducted by increasing the experimental temperature. Detail microstructural analysis is conducted using a scanning electron microscope, transmission electron microscope and energy dispersive spectrometer. After oxidation, a hematite structure oxide film is formed, and pitting corrosion occurs on the surface of specimens. Most of the pitting corrosion is found at the substrate surface because the corrosion resistance of the substrate, which has low Cr content, is relatively low. Also, the oxidation reaction of B in the secondary phase has the lowest Gibbs free energy compared to other elements. Furthermore, oxidation of Cr has low Gibbs free energy, which means that oxidation of B and Cr could be faster than other elements. Thus, the long-term corrosion might affect the boron content and the neutron absorption ability of the material. Using boron’s high cross-section for neutrons, the neutron absorption performance of BSS was evaluated through neutron transmission tests. The effect of the corrosion behavior of BSS on its neutron absorption performance was investigated. Samples simulated to undergo up to 60 years of degradation before corrosion through accelerated corrosion testing did not show significant changes in the neutron shielding ability before and after corrosion. This can be explained in relation to the corrosion behavior of BSS. Boron was only leached out from the secondary phase exposed on the surface, and this oxidized secondary phase corresponds to about 0.17% of the volume of the total secondary phase. This can be seen as a very small proportion compared to the total boron content and is not expected to have a significant impact on neutron absorption performance.

저자
  • Daehyeon Park(Ulsan National Institute of Science and Technology (UNIST))
  • Yunju Lee(Ulsan National Institute of Science and Technology (UNIST))
  • Junhyuk Ham(Ulsan National Institute of Science and Technology (UNIST))
  • Seung Chang Yoo(Korea Institute of Nuclear Safety (KINS))
  • Kiyoung Kim(Korea Hydro & Nuclear Power (KHNP))
  • Donghee Lee(Korea Hydro & Nuclear Power (KHNP))
  • Ji Hyun Kim(Ulsan National Institute of Science and Technology (UNIST)) Corresponding author