The thermal evaluations for the conceptual design of the deep geological repository considering the improved modeling of the spent fuel decay heat were conducted using COMSOL Multiphysics computational program. The maximum temperature at the surface of a disposal canister for the technical design requirement should not exceed 100°C. However, the peak temperature at the canister surface should not exceed 95°C considering the safety margin of 5°C due to several uncertainties. All thermal evaluations were based on the time-dependent simulation from the emplacement time of the canister to 100,000 years later. In particular, the heat source condition was set to the decay heat rate and axial decay heat profile of the PLUS7 fuel with 4.0wt% U-235 and 45 GWD/MTU. The thermal properties of the granitic rock in South Korea were applied to the host rock region. For the reference design case, the cooling time of the SNF was set to 40 years, the distance between the deposition holes 8 meters and that between the deposition tunnels 30 meters. However, the peak temperature at the canister surface at 10 years was 95.979°C greater than 95°C. This design did not meet the thermal safety requirement and needed to be modified. For the first modified case, when the distance between the deposition tunnels was set to 30 meters, three cooling time cases of 40, 50 and 60 years and five distances of 6, 7, 8, 9 and 10 meters between the deposition holes were considered. The design with the distances of 9 and 10 meters between the deposition holes for the cooling time of 40 years and all five distances for 50 and 60 years were less than 95°C. For the second modified case, when the distance between the deposition holes was set to 8 meters, three cooling time cases of 40, 50 and 60 years and five distances of 20, 25, 30, 35 and 40 meters between the deposition tunnels were considered. The design with the distances of 35 and 40 meters between the deposition tunnels for the cooling time of 40 years, the distances of 25, 30, 35 and 40 meters for 50 years and all five distances for 60 years were less than 95°C. As a result, the peak temperature at the canister surface decreased as the cooling time and the distance between the deposition holes and the tunnels increased.