논문 상세보기

Criticality Safety Analysis for Concrete Radioactive Waste Drums Using KENO-VI of SCALE

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/431378
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

Most of the radioactive wastes generated during the nuclear fuel processing activities conducted by KEPCO Nuclear Fuel Co., Ltd. are classified as the categories of intermediate and low-level radioactive waste. These radioactive waste materials are intended for permanent disposal at a designated disposal site, adhering strictly to the waste acceptance criteria. To facilitate the safe transportation of radioactive waste to the disposal site, it is necessary to ensure that the waste drums maintain a level of criticality that complies with the waste acceptance criteria. This necessitates the maintenance of subcritical conditions, under immersion or optimal neutron moderation conditions. This paper presents a criticality safety assessment of concrete radioactive waste under the most conservative conditions of immersion and moderation conditions for waste drums. Specifically, In order to send radioactive waste, which is the subject of criticality analysis, to a disposal facility, pre-processing operations must be performed to ensure compliance with waste accepatance criteria. To meet the physical characteristics required by the accepance criteria, particles below 0.2 mm should not be included. Thus, a 0.3 mm sieve is used to separate particles lager than 0.3 mm, and only those particles are placed in drums. The drums should be filled to achieve a filling ratio of at least 85%. A criticality analysis was conducted using the KENO-VI of SCALE. The Criticality Safety Analysis Results of varying the filling ratio of concrete drums from 85% to 100% presented in an effective multiplication factor of 0.22484. Additionally, the effective multiplication factor presented to be 0.25384 under the optimal moderation conditions. This demonstrates full compliance with the USL and criticality technology standards set as 0.95.

저자
  • Sanggeol Jeong(KEPCO Nuclear Fuel (KEPCO NF)) Corresponding author
  • Jang Hwan Lim(KEPCO Nuclear Fuel (KEPCO NF))
  • Seong Ki Lee(KEPCO Nuclear Fuel (KEPCO NF))