간행물

한국구조물진단유지관리공학회 논문집 KCI 등재 Journal of The Korea Institute for Structural Maintenance and Inspection

권호리스트/논문검색
이 간행물 논문 검색

권호

Vol.21. No.1 (2017년 1월) 166

61.
2017.01 서비스 종료(열람 제한)
In this study, multiple regression analysis was conducted using traffic volume, temperature and strain, which are maintenance data of suspension bridge(Diamond Bridge in Busan). As a result of analysis, the influence of independent variables on the dependent variable, strain, was found to be .304 for light and compact car traffic, .476 for large and special car traffic and .167 for the average temperature of reinforced truss.
62.
2017.01 서비스 종료(열람 제한)
This paper describes the electrical characteristics of carbon fiber reinforced cement composite under compressive loading. The test results indicated that the electrical resistance changes of cement composite in compression were improved with increasing carbon fiber volume fractions.
64.
2017.01 서비스 종료(열람 제한)
In this study, the effect of electromagnetic wave from an electronic device on electric sensor system and optic sensor were analyzed to verify the reduction effect of a optic sensor and applicability to marin structure. Test revealed that optic sensor system was not occurred the noise by electromagnetic waves also had the low range of fluctuation.
65.
2017.01 서비스 종료(열람 제한)
In the case of marine concrete composite structures, damaged by the various environment effect(sea damage, freeze-thaw, carbonation), and then, there is a possibility of going bad in the safety. The purpose of this study is to perform periodic measurements and tests on the durability test site constructed at sea and to provide basic guidelines for future maintenance based on the analyzed data.
66.
2017.01 서비스 종료(열람 제한)
PSC girder bridges, widely applied to bridge and railroad bridge (25 ~ 50 m), are a type of bridge that introduces compressive force in advance to the part where tensile force of concrete is generated. The tension force for introducing the compressive force by inserting the tendon into the concrete is a key element of the structural performance in the PSC. At present, however, measurement and verification of this is indirectly managed through deflection and cracking. However, it has become more necessary to develop practical evaluation methods of prestress force of PSC bridges. In this experiment, a small scale PSC beam with various curvature radii was made. Tension force monitoring with FBG sensor and EM sensor was performed on test members using 3 point flexural loading test. The measured values of the FBG sensors and the EM sensors used in the experiment were analyzed and compared with the measured values of the load cell.
67.
2017.01 서비스 종료(열람 제한)
Collapse of reinforced earth retaining wall due to improper design and construction is still occurring during construction and operation. While most studies of reinforced retaining walls are focused on the mechanistic behavior, there is little study on the improvement of assessment item, which is used to examine the safety of retaining wall, based on the existed inspection data. This study proposed new weighting factor of assessment item by utilizing multiple regression analysis technique, AHP method, and entropy method for the existed inspection data of reinforced earth retaining wall. Compared to the existed weighting factor, the value and the rank of proposed weighting factors are changed. By applying the proposed weighting factors to the existing retaining walls of 161 sites, fragility region of 47 sites is changed.
69.
2017.01 서비스 종료(열람 제한)
This study is a part of the research on the development of safety monitoring system and monitoring program of 3MW offshore wind support structure using fiber optic sensor. In this paper, we propose a maintenance system for offshore wind support structure using fiber optic sensor based on the analysis of current monitoring status and related standards of domestic and overseas offshore wind support jacket structures.
70.
2017.01 서비스 종료(열람 제한)
In this study, the risk matrix method was applied to reduce the number of post-tension survey in maintenance. The risk matrix weights and evaluation indexes were studied according to the maintenance system.
71.
2017.01 서비스 종료(열람 제한)
In this study, propose a building Online system based on information sharing that minimizes the unnecessary expenses used to for the management of slope face-map newly created through new road, extension and linear improvement. Also, as a result of the economic feasibility analysis by quantitatively estimating the initial invest costs and the benefits resulting from the cost reduction, the B/C ratio is evaluated to be 1.0 or more after 2 years, be used to effective management plan.
72.
2017.01 서비스 종료(열람 제한)
In this study, the case was analyzed for the repair of the reinforced earth wall during its construction. Such a problem is deemed to require more in-depth design and quality control.
74.
2017.01 서비스 종료(열람 제한)
Visual inspection has generally been applied to examine the coating deterioration. However, it was difficult to evaluate an anti-corrosion performance of paint film. In this study, thus, to quantitatively evaluate an anti-corrosion performance of paint film under various corrosion enviornent, change in the impedance paint coating was evauated using EIS (Electrochemical Impedance Spectroscopy).
75.
2017.01 서비스 종료(열람 제한)
Web-based DB design standards of the Reservoir Failure Forecasting System are proposed in order to actively respond to the user’s work changes, various sensors, and business logic, and increase the system usability by reducing logic changes and client maintenance through minimal interface changes.
76.
2017.01 서비스 종료(열람 제한)
This study is for the damage with lack of drain pipe length and it is presented for the improved references which is 「Design and management guidelines of road drainage facilities」.
77.
2017.01 서비스 종료(열람 제한)
We have studied the optimum location of the sensor to evaluate the condition of the structure by performing the structural analysis on the landing pier. It is judged that it is appropriate to place the strain sensor of the landing pier at the upper part, the middle part and the upper part of the pile at 30% below the pile.
78.
2017.01 서비스 종료(열람 제한)
We have studied the optimum location of the sensor to evaluate the condition of the structure by performing the structural analysis on the landing pier. It is judged that it is appropriate to place the strain sensor of the landing pier at the upper part, the middle part and the upper part of the pile at 30% below the pile.
79.
2017.01 서비스 종료(열람 제한)
This paper introduces and summarizes damage cases of cable for cable supported bridges. The damage cases of similar bridge types may become an important database in the maintenance and management of cable supported bridges in the future. It will also be used as a base material for improving and developing the technology of inspection and maintenance of cable supported bridges.
80.
2017.01 서비스 종료(열람 제한)
Domestic infrastructure facilities were built intensively in the 1970s and 1990s, and the resources required for maintenance and repair will increase sharply within the next 20 years. ‘A Comparative Study on the Classification and Financial Size of SOC(2012)’ showed that the size of the domestic infrastructure facility is shrinking. In this study, we investigated the case of asset management research and analyzed the trend of the aging of the domestic infrastructure. And then we present the direction of future research.
1 2 3 4 5