간행물

한국구조물진단유지관리공학회 논문집 KCI 등재 Journal of The Korea Institute for Structural Maintenance and Inspection

권호리스트/논문검색
이 간행물 논문 검색

권호

Vol.21. No.6 (2017년 12월) 25

1.
2017.12 서비스 종료(열람 제한)
Spiral reinforcement in a circular column plays an effective role in the ductile behavior of a column through position fixing and buckling restraining of the longitudinal reinforcement, and confining core-concrete. Each country has suggested the minimum volumetric ratio of spiral reinforcement in order to secure the ductility of concrete columns. The minimum volumetric ratio of spiral reinforcement suggested by ACI 318-14 and the national concrete structure design standard was developed based on the theory of Richard et al. (1928); furthermore it has been used until now. However, their theory cannot consider the effects of high strength concrete and high strength reinforcement, and arrangement condition of the spiral reinforcement. In this study, a modified minimum volumetric ratio equation is suggested, which is required to improve the ductility of reinforced concrete circular columns and to recover their stress. The modified minimum volumetric ratio equation suggested here considers the effect of the compressive strength of concrete, the yield strength of spiral reinforcement, the cross sectional area of columns, the pitch of spiral reinforcements and the diameter of spiral reinforcement. In this paper, the validity of the minimum volumetric ratios from ACI 318-14 and this study was investigated and compared based on the results of uniaxial compression experiment for specimens in which the material strength and the spiral reinforcements ratio were used as variables. In the end of the study, the modification method for the suggested equation was examined.
2.
2017.12 서비스 종료(열람 제한)
The refraction expansion joints have been newly developed by complementing the problems of shock, noise, replaceability, displacement in the direction perpendicular to bridge, vertical difference, which are problems of existing expansion joints. The Refraction expansion joints are characterized by continuous surfaces with small impact and low noise. The behavior of the Refraction expansion joints performs the bridge expansion behavior by rotation of the link. In the rotational behavior of the link, the bolt is the central axis of the behavior. Therefore, it can be said that the durability of the bolt is very important. However, the theoretical and experimental verification of the bolt durability of the Refraction expansion joint is lacking. In this paper, to verify the fatigue durability of the bolt, test specimens with a 300 mm Refraction expansion joint were fabricated. A strain gauge dedicated to the bolt was installed inside the manufactured test specimen bolt. The test method was applied in accordance with KS F 4425. The fatigue durability of the bolts assembled inside the diaphragm expansion joint was confirmed by the repeated fatigue test of 2,000,000 cycles.
3.
2017.12 서비스 종료(열람 제한)
The purpose of this paper is to search the optimal location of offset outrigger system in high-rise building after a structural schematic design of 80 stories building was conducted, making use of MIDAS-Gen. In this research, the key factors of analysis study were column stiffness, outrigger position in plan and outrigger location in height. For the aim of finding out the optimum position of offset outrigger system in tall building, we studied the lateral displacement in top floor which is the very essential variables in the structural design of high-rise building. The results of study showed that the column stiffness, the outrigger location in plan and outrigger location in height had an effect on the optimal position of outrigger system. Also, it is indicated that the research results can be useful in acquiring the structural design materials for seeking the optimum position of offset outrigger system in tall building.
4.
2017.12 서비스 종료(열람 제한)
Since the 30-year-old facility is expected to surge from 10.5% to 23.9% in 10 years, the new evaluation system is needed to establish efficient maintenance system for securing the safety and extending the life span of existing facilities. In this study, Delphi and AHP(Analytic Hierarchy Process) was conducted to provide a systematic new evaluation system for the NATM tunnel, which is the most frequently constructed structure of the existing tunnel. Since the existing assessment systems are limited in scope of evlauatuon criteria, the survey was conducted in conjunction with closed questionnaires on existing items and open questionnaires for eliciting new items. In results, suitable evaluation factors were derived for the NATM tunnel through the validation of the survey results. Also after calculating weighted value of the derived assessment item using AHP technique, a new evaluation system is proposed to meet the characteristics of the NATM tunnel, so that they can be used as reference materials for revising and supplementing detatiled guidelines in the future.
5.
2017.12 서비스 종료(열람 제한)
The minimum reinforcement ratio is an important design factor to prevent a brittle failure in RC flexural members. A minimum reinforcement ratio is presented by assuming an effective depth of cross-section and moment arm lever in CDC and KHBDC. In this study, it suggests that a rational method for minimum reinforcement ratio is calculated by material model and force equilibrium. As results, a minimum reinforcement ratio using a p-r curve in KHBDC is evaluated about 52~80% of recent design code’s value and it induces an economical design. And also, a ductility capacity in case of placing this minimum reinforcement amount is evaluated about 89% of recent design code’s value, but ductility in a member is 7 or more, so it has a sufficient ductility capacity. Therefore, it is judged that a minimum reinforcement ratio using p-r curve has a theoretical rationality, safety and economy in a flexural member design.
6.
2017.12 서비스 종료(열람 제한)
Recently, the parking in downtown area has caused severe problem due to the dramatic increase of possessing automobile in the country. A parking structure has been on the spotlight to solve the parking problem in downtown area. However, the overall height of parking structure is stipulated less than 8 m. Therefore, in this research, ‘wide composite beam’, which is possible for reducing story height and having long span, is developed and the flexural capacity of the wide composite beam is evaluated. Based on the result of the flexural test, the flexural strength of wide composite beam increased by 20% as the thickness of steel beam increased by 3 mm (6 mm → 9 mm) The shapes of rebar (whether it is triangle or rectangular shape) in the wide composite beam did not affect its flexural strength. The flexural strength of wide composite beam without rebar decreased by 10% compared to that of wide composite beam with rebar. In addition, the neutral axis moved upward as a load increased, but the neutral axis moved downward, when the load exceeded a certain level of load.
7.
2017.12 서비스 종료(열람 제한)
Concrete made with ground granulated blast-furnace slag(GGBS) has many advantage, including improved durability, workability and economic benefits. GGBS concrete is that its strength development is considerably slower under standard 20°C curing conditions than that of portland cement concrete, although the ultimate strength is higher for same water-binder ratio. GGBS is not therefore used in application where high early age strength is required. In this study, to overcome the limitation of the initial strength decrease due to the use of slag, the slag substitution rate was changed to 30% under the low temperature curing temperature condition and the slag used concrete composition with the same or higher strength performance as OPC(Ordinary Portland Cement).
8.
2017.12 서비스 종료(열람 제한)
In the case of fluid storage structure, hydrostatic pressure acts on the structure due to fluid surge during an earthquake. At this time, hydrodynamic pressure of the fluid charge not only by the strength of the earthquake but also by the sloshing height of the fluid. Factors affecting the change of load include the size, width and height of the fluid storage structure and height of fluid, time-history shape, etc. This paper wanted to identify the relationship between the earthquake shape and fluid free surface shape. The sloshing height measured the height of the fluid by applying earthquake to a tank whose width 500mm and comparison of the experiment and analysis. In addition, the shape of the fluid free surface was measured while varying the shape of earthquake and effective of the shape of earthquake of the fluid was analyzed.
9.
2017.12 서비스 종료(열람 제한)
Recently, the demand for large diameter piles has been rapidly increased in order to secure the allowable bearing capacity of pile foundation due to the increase of large structures such as high rise buildings. In this study, to improve the shear capacity of a conventional PHC pile, a large diameter composite PHC pile strengthened by in-filled concrete and shear reinforcement was manufactured. All the piles were tested according to the shear strength test method of Korean Standard. As a result of the shear test, the F-type piles which are produced without shear reinforcement occurred abrupt horizontal cracks after flexural and inclined shear cracks occurred. On the contrary, the FT-type piles which are produced with shear reinforcement exhibited stable flexural and inclined shear cracks uniformly over the entire pile without abrupt horizontal cracks. Furthermore, the maximum load of the large diameter composite PHC pile improved to 2.9 times in the F series, and more than 3.3 times in the FT series compared to the conventional PHC pile. This result indicated that FT-type piles had excellent composite behavior due to the shear reinforcement and effectively prevented the unstable growth of inclined shear cracks.
10.
2017.12 서비스 종료(열람 제한)
This research presents the results of the strength and drying shrinkage properties to study the effect of ground granulated blast furnace slag(GGBFS), fly ash(FA) and calcium sulfoaluminate(CSA) for activated ternary blended slag cement. The activated ternary blended cement(ATBC) mortar were prepared having a constant water-cementitious materials ratios of 0.4. The GGBFS contents ratios of 100%, 80%, 70% and 60%, FA replacement ratios of 10%, 20%, 30% and 40%, CSA ratios of 0%, 10%, 20% and 30% were designed. The superplasticizer of polycarboxylate type were used. The activator was used of 10% sodium hydroxide(NaOH) + 10% sodium silicate(Na2SiO3) by weight of binder. Test were conducted for mini slump, setting time, V-funnel, water absorption, compressive strength and drying shrinkage. According to the experimental results, the contents of superplasticizer, V-funnel and compressive strength increases with an increase in CSA contents for all mixtures. Moreover, the setting time, water absorption ratios and drying shrinkage ratio decrease with and increase in CSA. One of the major reason for the increase of strength and decrease of drying shrinkage is the accelerated reactivity of GGBFS with alkali activator and CSA. The CSA contents is the main parameter to explain the strength development and decreased drying shrinkage in the ATBC.
11.
2017.12 서비스 종료(열람 제한)
Concrete structure for nuclear power plant is mass concrete structure with large wall depth and easily permits cracking in early age due to hydration heat and drying shrinkage. It always needs cooling water so that usually located near to sea shore. The crack on concrete surface permits rapid chloride intrusion and also causes more rapid corrosion in the steel. In the study, the effect of age and crack width on chloride diffusion is evaluated for the concrete for nuclear power plant with 6000 psi strength. For the work, various crack widths with 0.0~1.4 mm are induced and accelerated diffusion test is performed for concrete with 56 days, 180days, and 365 days. With increasing crack width over 1.0mm, diffusion coefficient is enlarged to 2.7~3.1 times and significant reduction of diffusion is evaluated due to age effect. Furthermore, apparent diffusion coefficient and surface chloride content are evaluated for the concrete with various crack width exposed to atmospheric zone with salt spraying at the age of 180 days. The results are also analyzed with those from accelerated diffusion test.
12.
2017.12 서비스 종료(열람 제한)
The purpose of this study is to get a more precise frequency of hollow core slabs by comparing the observed values from the actual free vibration tests and the predicted values based on the analysis model. The actual free vibration tests were carried out in the construction field using Ω shaped hollow core slabs. Modal analysis is conducted based on the analysis model that takes into account the differences in section properties due to void parts of slab. The differences between the predicted values based on the modal analysis with analysis model and the measured data from the actual tests range from 2~7%. This study demonstrates that the analysis model that incorporates void parts of slab could be used in evaluating serviceability of hollow core slabs with reasonable accuracies.
13.
2017.12 서비스 종료(열람 제한)
In this study, the fiber blending ratio and strain rate effect on the tensile behavior of hybrid fiber reinforced cement composite was evaluated. Hooked steel fiber and polyvinyl alcohol fiber were used for reinforcing fiber. The fiber blending ratio of HSF+PVA were 1.5+0.5, 1.0+1.0 and 0.5+1.5vol.%. As a results, the tensile strength, strain capacity and fracture toughness of the hooked steel fiber reinforced cement composites were improved by the increase of the bond strength of the fiber and the matrix according to increase of strain rate. However, the tensile stress sharply decreased after the peak stress because of the decrease in the number of straightened pull-out fibers by micro cracks in the matrix around hooked steel fiber. On the other hand, PVA fiber showed cut-off fracture at strain rate 10-6/s with multiple cracks. However, at the strain rate 101/s, the multiple cracks and strain capacity were decreased because of the pull-out fracture of PVA fiber. The HSF1.5PVA0.5 shown the highest tensile strength because the PVA fiber suppressed the micro cracks in the matrix around the hooked steel fiber and improved the pull-out resistance of hooked steel fiber. Thus, DIF of strain capacity and fracture toughness of HSF1.5PVA were greatly improved. In addition, the synergistic response of fracture toughness was positive because the tensile stress was slowly decreased after the peak stress by improvement of the pull-out resistance of hooked steel fiber at strain rate 101/s
14.
2017.12 서비스 종료(열람 제한)
This paper presents a mathematical model derived from the upper-bound theorem of concrete plasticity to rationally evaluate the shear friction strength of concrete interfaces with a construction joint. The upper limit of the shear friction strength was formulated from the limit state of concrete crushing failure on the strut-and-tie action along the construction joints to avoid overestimating the shear transfer capacity of a transverse reinforcement with a high clamping force. The present model approach proposed that the cohesion and coefficient of friction of concrete can be set to be 0.27(fck)0.65 and 0.95, respectively, for rough construction joints and 0.11(fck)0.65 and 0.64, respectively, for smooth ones, where fck is the compressive strength of concrete. From the comparisons with 155 data compiled from the available literature, the proposed model gave lower values of standard deviation and coefficient of variation of the ratios between predictions and experiments than AASHTO and fib 2010 equations, indicating that the proposed model has consistent trends with test results, unlike the significant underestimation results of such code equations in evaluating the shear friction strength.
15.
2017.12 서비스 종료(열람 제한)
In spite of bulk literature about the tuning of TMD, the effectiveness of TMD in reducing the seismic response of engineering structures is still in a row. This paper deals with the optimum tuning parameters of a passive TMD and simulated on MATLAB with a ten-story numerical shear building. A weighted multi-objective optimization method based on computer experiment consisting of coupled with central composite design(CCD) central composite design and response surface methodology(RSM) was applied to find out the optimum tuning parameters of TMD. After the optimization, the so-conceived TMD turns out to be optimal with respect to the specific seismic event, hence allowing for an optimum reduction in seismic response. The method was employed on above structure by assuming first the El Centro seismic input as a sort of benchmark excitation, and then additional recent strong-motion earthquakes. It is found that the RSM based weighted multi-objective optimized damper improves frequency responses and root mean square displacements of the structure without TMD by 31.6% and 82.3% under El Centro earthquake, respectively, and has an equal or higher performance than the conventionally designed dampers with respect to frequency responses and root mean square displacements and when applied to earthquakes.
16.
2017.12 서비스 종료(열람 제한)
Numerical analysis using commercial CFD code was carried out to develop the drag force type vertical axis hydraulic turbine for the improvement of the production efficiency of small hydro energy at low flow velocity condition. Blade pressure changes and internal flows were analyzed according to the presence or absence of the hydraulic turbine blade holes at flow velocity of less than 1.0~3.0 m/s. According to the numerical results, the pressure and flow velocity is severly affected by the flow velocity in turbine blade with no holes, while the influence of flow velocity is comparatively decreased in turbine blade with holes. It is also found that the pressure and flow velocity on the blade surface with holes are evenly distributed with no singular location and it is believed that forming a hole in the blade may be helpful in terms of structural safety.
17.
2017.12 서비스 종료(열람 제한)
A huge amount of de-icing agent is sprayed during winter to promote traffic safety in cold regions, and the quantity of de-icing agent sprayed has increased each year. The main ingredients in commonly used de-icing agents are chlorides, such as calcium chloride(CaCl2) and sodium chloride(NaCl). While calcium chloride is mostly used in Korea and sodium chloride is usually used in the U.S. and Japan, all de-icing agents include chloride ions. The chlorides included in sprayed calcium chloride-based de-icing agents have severe adverse effects, including the corrosion of reinforcing steels through salt damage by infiltrating into road structures, reduced structural performance of pavement or damage to bridge structures, and surface scaling, in combination with freezing damage in winter, as well as water pollution. In addition, the deterioration of paved concrete road surface that occurs after the use of calcium chloride-based de-icing agent accelerates the development of visual problems with traffic structures. Therefore, the present study was performed to prepare an environment-friendly liquid de-icing agent through a reaction between waste organic acids and calcium-based by-products, which are industrial by-products, and to analyze the properties of the de-icing agent in order to evaluate its applicability to road facilities.
18.
2017.12 서비스 종료(열람 제한)
표준 시료의 분광 분석으로부터 획득한 각 원소별 파장 특성 값과 검사대상 미지 시료로부터의 파장 분석 결과를 비교함으로써 미 지 시료에 함유된 원소의 정성 및 정량 분석을 가능하게 하는 것이 LIBS이다. 본 연구에서는 콘크리트 내구성에 영향을 미치는 주요 열화 요인 을 규명하는 것에 대하여 LIBS의 적용 가능성을 실험적으로 분석하였다. 즉, LIBS를 통해 염화물, 황산염, 탄산화 모르타르 시험체에 대한 유 해 열화인자 정량 검출 실험을 실시함으로써 콘크리트 열화 진단의 LIBS 적용 가능성을 연구하였다. 염화물과 황산염 시험체 각각에 대하여 LIBS 실험을 실시한 결과 농도가 증가할수록 염소 및 황 이온의 LIBS 스펙트럼 파장 강도가 선형적으로 증가하는 것을 알 수 있었다. 탄산화 시 험체의 경우 탄산화 노출 기간에 따른 탄소 이온 LIBS 스펙트럼 파장 강도는 다소 비선형적으로 증가하는 것으로 나타났다. 이상의 실험결과 로부터 콘크리트 열화 진단에 LIBS의 적용가능성을 부분적으로 확인할 수 있었으며, 콘크리트 탄산화의 경우 시멘트 자체에 탄소 성분이 함유 되어 염화물 및 황산염 시험체의 정량 검출과는 다소 상이한 결과를 보인 것으로 추정된다. 따라서 콘크리트 탄산화에 대하여 LIBS를 적용하 기 위해서는 보다 다양한 매개변수 연구가 수행되어야 할 것으로 사료된다.
19.
2017.12 서비스 종료(열람 제한)
일반적으로, 원전구조물은 다량의 철근이 사용되어 시공과정에서 여러 잠재적 문제점이 발생한다. 특히, 구조부재의 연결부위는 수많은 갈고리철근, 매입철물과 주변 철근 등에 의해 심각한 과밀현상이 발생하므로 여타 다른 부위보다 콘크리트 타설에 더 큰 어려움이 야기 된다. 원전구조물에 사용되는 일반강도(ASTM A615 Gr.60)의 대구경(43 mm & 57 mm) 표준갈고리 철근을 대신하여 고강도(ASTM A615 Gr.80)의 대구경(43 mm & 57 mm) 확대머리 철근을 사용할 수 있도록 관련 기술기준을 개정하여 철근 과밀배근 문제를 해결하는 데 본 연구의 목적이 있다. 확대머리 철근을 원전구조물에 효과적으로 사용하기 위해서는 기존의 정착성능을 그대로 유지하거나 그 이상으로 증가시키면서 사용 제한요건을 완화는 방안을 찾아야 하므로 철근직경, 철근 항복강도, 측면피복 두께와 같이 확대머리 철근의 사용을 제한하는 변수 영향을 검토할 수 있는 실험결과를 분석하여 정착성능을 평가하였다.
20.
2017.12 서비스 종료(열람 제한)
탄소나노튜브는 고강도, 고내구성 콘크리트의 생산을 위한 새로운 재료 중 하나로 여겨지며, 많은 연구자들에 의하여 연구되고 있 다. 탁월한 열전도도는 향후 자가발열 콘크리트의 개발에 필수적이며, 이 연구에서는 다양한 목적을 갖는 콘크리트의 개발을 위한 역학적 특성 및 미세구조 분석을 실시하였다. CNT 첨가량은 시멘트 중량대비 0.115, 0.23, 0.46wt%로 하였다. 압축강도/휨강도 시험은 재령 3, 7, 28일에 실 시하였으며, 공극률은 MIP 시험을 통해 실시하였다. CNT 분산성 및 수화생성물 분석을 위하여, SEM 분석 및 열분석을 실시하였다. 그 결과, CNT 첨가에 따른 역학성능은 다소 감소하는 경향을 나타내었으나, 0.115wt% 첨가한 경우 플레인 배합과 동등 수준의 결과를 확인할 수 있었 다. 향후, 기존 콘크리트와 동일한 역학성능을 보유한 CNT 첨가 배합의 개발을 통한 발열성능 확보가 가능할 것으로 기대된다.
1 2