According to the recently revised seismic design standards, seismic design of underground structures is required. Concrete underground outer walls are installed separately from temporary earth retaining walls as permanent underground outer walls. This raises issues of constructability, economy, and space narrowness. Therefore, a steel underground continuous wall is developed to promote construction efficiency, safety, and economy by introducing the off-site construction (OSC) method of underground structures. The steel underground continuous wall will be used as a permanent underground continuous wall along with the temporary earth retaining wall. To this end, it must satisfy structural performance equivalent to or higher than the concrete underground outer wall. The integrity and in-plane shear resistance performance between single panel members must be satisfied to be used as a permanent wall. The interlocking effect through geometric bonding is intended to enhance the bonding effect between these members. Therefore, trapezoidal members were developed, and bending performance tests and analyses of each member were performed to confirm the structural bending performance of these members. The bending performance improvement effect of the combined multiple members was confirmed. As a result, it was confirmed that the integration of members and structural performance was improved due to the interlocking effect of the absence of joints. The seismic design analysis of the demonstration site was performed with these developed members, and it was confirmed that the structural performance was equivalent to or higher than that of the existing RC underground continuous wall. As a result, it was confirmed that the steel underground continuous wall can be used as a permanent underground wall together with the temporary earth retaining wall.
In this paper, a dynamic centrifuge model test was conducted on a 24.8-meter-deep excavation consisting of a 20 m sand layer and 4.8 m bedrock, classified as S3 by Korean seismic design code KDS 17 10 00. A braced excavation wall supports the hole. From the results, the mechanism of seismically induced earth pressure was investigated, and their distribution and loading points were analyzed. During earthquake loadings, active seismic earth pressure decreases from the at-rest earth pressure since the backfill laterally expands at the movement of the wall toward the active direction. Yet, the passive seismic earth pressure increases from the at-rest earth pressure since the backfill pushes to the wall and laterally compresses at it, moving toward a passive direction and returning to the initial position. The seismic earth pressure distribution shows a half-diamond distribution in the dense sand and a uniform distribution in loose sand. The loading point of dynamic thrust corresponding with seismic earth pressure is at the center of the soil backfill. The dynamic thrust increased differently depending on the backfill's relative density and input motion type. Still, in general, the dynamic thrust increased rapidly when the maximum horizontal displacement of the wall exceeded 0.05 H%.
Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.
The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.
The home meal replacement (HMR) food industry began in 1980, and it has grown rapidly as a major food business for both consumers and the food industry since the development of industrialization and societal changes. Many researchers investigated a variety of HMR food product characteristics. On the other hand, previous studies have focused only on topics in limited study areas. Therefore, this study examined the effect of color marketing and the value of experience on the consumer behaviors. This study used a survey to collect the respondents' opinions about HMR food products. The study results showed that the characteristics of color marketing and the experience value of the HMR products influenced the consumers' attitudes. Moreover, consumers' attitudes affected their repurchase behavior. The results suggest that marketers of HMR food products should use colors that show the characteristics of products to appeal to consumers. In addition, HMR products should be developed in line with what consumers value the most; for example, consumers value their previous experience with the products and the characteristics of the products.
In this study, Stockbridge damper was adopted to reduce the reponses of structures under earthquakes. A finite element analysis software, SAP2000, was used to simulate the structural response and the control device under dynamic loads. A 3 story frame model and the proposed control device, Stockbridge damper, were designed under laboratory conditions. In this research, a pendulum type tuned mass damper (PTMD) was also adopted in order to compare with the Stockbridge damper. Harmonic loads were applied to verity the control performance of both control devices in each mode. In results, it has been found that the Stockbirdge damper decreases significantly the responses of the structure more than the PTMD under the harmonic loadings. The El Centro and Northridge earthquakes were also applied in order to investigate the performance by both control devices. The responses of the building demonstrate that the Stockbridge damper reduces the response of the building structure during earthquakes more effectively than the PTMD.
It is very important to assure the seismic performance of equipment as well as building structures in seismic design of nuclear power plant(NPP). Seismically isolated structures may be reviewed mainly on the horizontal seismic responses. Considering the equipment installed in the NPP, the vertical earthquake responses of the structure also should be reviewed. This study has investigated the vertical seismic demand of seismically isolated structure by lead rubber bearings(LRBs). For the numerical evaluation of seismic demand of the base isolated NPP, the Korean standard nuclear power plant (APR1400) is modeled as 4 different models, which are supported by LRBs to have 4 different horizontal target periods. Two real earthquake records and artificially generated input motions have been used as inputs for earthquake analyses. For the study, the vertical floor response spectra(FRS) were generated at the major points of the structure. As a results, the vertical seismic responses of horizontally isolated structure have largely increased due to flexibility of elastomeric isolator. The vertical stiffness of the bearings are more carefully considered in the seismic design of the base-isolated NPPs which have the various equipment inside.
An application of the EQS (Eradi Quake System) bearings to a short period building structure and the structure earthquake responses according to the design parameters of the EQS are studied by the ICT Center case study. The features of the EQS application to seismic isolated building structures are investigated, and the design procedure to determine the yield load and the secondary stiffness of the EQS is also studied. A computational analysis is performed to confirm the applicability of the EQS to the building structure and the earthquake responses according to the design parameters. The ICT Center in Indonesia is adopted as an application case of the EQS. The application of the EQS is found to extend the fundamental period of the ICT Center. Three types of EQS with different yield loads and secondary stiffness are designed and applied in the earthquake response analyses. The analysis results show the response of the structure with respect to the design parameters and which type of EQS is suitable for the ICT Center.
최근 국내에서는 원자력발전소의 모듈화 공법에 적용하기 위하여 SC(steel plate concrete) 구조를 개발하는 연구를 진행하고 있다. 이 연구에서는 전단보강이 없는 비보강 SC 전단벽의 횡방향 내진성능 및 강성특성에 대하여 분석하기 위하여 전단벽 모형시편을 제작하고, 이를 대상으로 정적가력실험을 수행하였다. 실험 결과를 이용하여, 이 논문에서는 비보강 SC 구조의 횡력에 대한 파괴모드의 유형을 분석하고, 단면강도와 부재의 강성 특성을 검토하였다. 그리고 SC 구조용 설계기준에서 제시하는 단면의 강도 계산식과실험결과를 비교하였다. 연구결과, 비보강 SC 전단벽의 파괴 형태의 하나는 콘크리트와 강판의 부착 상실로 인한 휨전단파괴라는 사실을발견하였다. SC 구조 전단벽의 벽체 길이방향 거동은 파괴 시까지 벽체 외측의 강판이 내부 콘크리트를 구속하는 효과를 기대할 수 있으므로 연성능력이 향상되는 것이 확인되었다
원자력발전소에 설치되는 안전관련 캐비닛형 전기기기는 설치 전에 내진검증이 요구된다. 전기기기의 동특성분석은 내진 검증에 포함된 중요한 과정이며, 기기의 정확한 해석모델을 작성하기 위해서도 필수적으로 요구되는 업무이다. 이 연구에서는 입력진동수준에 따른 기기의 동특성 변화를 분석하기 위하여 원전 지진감시시스템 캐비닛을 대상으로 진동대시험을 수행하고, 입력진동운동의 수준별로 계측된 진동응답신호를 진동수영역분해법으로 분석하였다. 분석결과, 대상기기는 입력진동수준의 크기에 따라 동특성이 비선형적으로 변화하고, 국내 원전의 안전정지지진 수준 이하의 진동에서도 동특성이 비선형적 거동을 보이고 있음을 확인하였다. 이러한 입력진동 수준에 따라 전기기기의 동특성이 비선형적으로 변하는 원인은 대상기기의 특성과 입력진동수준을 고려할 때 일반적인 재료 비선형보다는 각 부품들의 마찰력과 기하학적인 비선형성에 기인하는 것으로 판단된다. 따라서 전기 캐비닛의 입력진동수준에 따른 동특성의 비선형적 변화는 향후 안전관련 기기의 내진검증 업무에서 중요하게 검토되어야 할 것으로 판단된다.
본 연구는 원자력발전소에 설치되는 캐비닛형 전기기기의 동적 진동시험 자료를 이용하여 캐비닛의 지진응답을 예측할 수 있는 기법을 제안하였다. 제안된 기법은 1) 절점질량 이상화 모델에 기반한 등가 지진하중 산정, 2) 진동시험자료에 기반한 캐비닛 구조의 입출력 상태방정식 규명, 3) 산정된 등가지진하중과 규명된 입출력 상태방정식을 사용한 지진응답산정의 과정으로 구성된다. 제안된 기법은 유한요소기법(FEM) 모델 개선(Model Updating)에 기반한 지진응답예측기법에 비하여 모델링 오차가 개입 되지 않는 장점을 가진다. 캐비넷 구조를 이상화한 2차원 프레임 모델과 3차원 상세 모델에 대한 수치검증을 통하여 제안된 기법이 지진응답을 매우 정확하게 예측을 함을 관찰하였고, 측정 노이즈에 대해서도 강인함을 관찰하였다. 추후연구로 실험검증이 요구된다.
다층구조물의 경우 변위보다 층간변위에 의해 구조물의 파괴가 발생되나 현행 국 내외 내진설계 규준에 제시된 역량스펙트럼 법에서는 변위에 의한 응답산정으로 층간변위를 정확히 예측할 수가 없었다. 따라서 본 논문에서는 다층구조물의 가장 기본적인 모델인 전단빌딩(Shear Building)에 대하여 기존의 역량해석법의 간편성과 장점을 변함없이 유지하면서, 구조물의 파괴에 직접적인 영향을 미치는 층간변위를 실제에 가깝게 예측하고 구조물의 내진성능을 평가할 수 있는 개선된 역량스펙트럼 법을 제안하고자 한다. 나아가 제안된 방법을 예제구조물에 적용하고 시간이력 해석결과와 비교함으로서 제안된 방법의 신뢰성에 대한 검증을 수행하였다.
본 연구에서는 수중에 잠긴 하나로 유동관에 작용하는 유체에 의한 동적유체질량이 유동관의 동적 거동과 지진응답에 미치는 영향에 대해서 연구하였다. 우선 구조물의 주변 유체를 유한요소로 모형화하여 수중에 잠긴 유동관의 단위길이당 작용하는 동적유체질량을 구하였다. 유한요소법으로 구한 동적유체질량을 사용하여 수중에 잠긴 실제의 육각형 유동관에 관하여 동특성 해석과 지진응답스펙트럼 해석을 한 후에, 유동관의 동적특성실험으로부터 계측한 결과와 비교/검증하였다. 여러가지 방법을 사용하여 유동관에 작용하는 유체의 동적유체질량을 구한 후에, 이를 사용하여 수중에 잠긴 유동관을 동적 해석하였다. 여기서 구한 결과들을 비교/검토하여 실제의 하나로 유동관의 동적 해석에 사용할 수 있는 적합한 기준을 제시하였다.
본 연구에서는 지하철구조물, 터널구조물 및 제방 등과 같은 2차원 지반-구조계의 지진응답해석을 위한 주파수영역 동적해석법을 제시하였다. 제시한 방법에서는 구조물과 구조물 주변 근역지반은 유한요소를 이용하고 원역지반은 주파수종속 동적무한요소를 이용하여 모형화하였다. 지진입력은 입력지진파를 수직으로 입사하는 P-파와 SV-파로 가정하여 자유장응답을 구하였으며 외부고정경계법을 적용하여 등가지진하중을 산정하였다. 본 연구기법의 검증을 위하여, 층상 자유장지반과 균질 반무한지반에 매입된 원동형 공동에 대하여 지진응답을 수행하였다. 이들을 다른 기법에 의한 해와 비교한 결과, 본 연구의 기법이 매우 정확함을 알 수 있었다. 마지막으로 지하철 역사의 지진응답해석 예제를 제시하여 본 연구의 적용성을 보였다.
본 논문에서는 랜덤한 축대칭 기하학적 초기결함을 갖는 원통이 축방향 충격하중을 받는 경우의 반경방향 변위가 임계기준치를 최초로 통과하는 확률론적 충격좌굴 파괴시간을 해석할 수 있는 방법을 제시하였다. 랜덤한 기하학적 초기결함의 생성을 위해 초기결함의 평균함수 및 상관함수를 이용하여 확률장을 형성하는 방법을 사용하였다. 본 논문에서 제시된 방법은 실제적인 기하학적 초기결함이 갖는 불확실성을 취급하는데 적절하고 실용적이므로 이를 고려한 원통의 구조안전도해석에 이용할 수 있다.
구조물의 손상추정법은 정적방법과 동적방법으로 나눌 수 있다. 정적방법은 정적하중과 정적변위의 관계를 이용하여 구조물의 손상위치와 손상정도를 추정하는 방법으로 동적방법에 비해 수식이 간단하나, 정적하중과 정적변위의 관계만을 사용하여 구조물의 손상을 추정하므로 정적변위에 대한 오차에 매우 민감하다. 동적방법은 구조물의 고유한 진동특성을 나타내는 고유진동수와 진동모우드를 구하여 구조물의 손상을 추정하는 방법으로, 정적방법에 비해 동일한 측점에서 많은 양의 시간기록자료를 계측할 수 는 있으나, 신뢰성이 높은 많은 수의 고유진동수와 진동모우드를 구하기가 어렵다. 본 연구에서는 구조물의 정적변위, 고유진동수와 진동모우드에 대한 민감도행렬을 사용하여 구조물의 정적 및 동적특성을 동시에 고려할 수 있는 구조물의 손상추정법을 제시하였다. 제시한 방법은 구조물의 손상 전.후의 정적변위와 진동모우드의 변화량을 부등구속조건식으로한 최적화기법을 사용하므로, 제한된 계측절점과 오차를 고려할 수 있으며 정적변위와 모우드 민감도행렬이외의 다양한 구조적 특성에 대한 민감도를 구속조건식으로 사용할 수 있다. 트러스구조물에 대한 모의 수치예제를 통한 제안한 방법의 정확성과 효율성을 수치적으로 검증하였다.
Failure risk investigation of any structure in a seismic zone can be done by the seismic probabilistic risk assessment (SPRA), which became a very attractive area of research in terms of safety measurement. This paper introduces such kind of concept to identify which magnitude in a specific seismic zone will contribute more vulnerable failure point in a structure. Here, for implement this idea a case study on a concrete gravity dam has been carried out. In order to make a correlation between the magnitude and failure risk contribution based on different damage stage, a combination of seismic hazard analysis and the probability of structural collapse is adopted. Therefore, the deaggregation of the mean annual frequency of failure risk by magnitude is used in this study to quantify four different limit stages of failure identification criteria. Consequently, from analyzing the result, in case of concrete gravity dam, this deaggregation approach shows the tensile crack in the base looks more vulnerable damage stage for the specific seismic zone.
This paper concern the performance of tuned mass damper (TMD) and dynamic behaviour of TMD controlled structure considering constitutive material model. A three-storied reinforced concrete frame is modelled using OpenSees for this study. Considering the non-linear materials model, the performance of the TMD not only rely on the mass, stiffness and damping of the system but also on the parameter to be controlled by TMD and the input ground motion types. For this reason in this study some practical, sine sweep and damped sine sweep are considered as input excitation to the evaluate exact dynamic behaviour of TMD controlled structure.
이 연구에서는 교량 주요부재의 내진보강 우선순위를 합리적으로 결정하는데 그 목적이 있다. 평가대상으로 케이블 교량을 선정하였으며 정량적 지표인 주요부재의 취약도를 평가하기 위해 확률분포에 근거한 신뢰도를 활용하였다. 확률변수인 안전계수는 주하중(고정하중, 활하중)과 부하중(지진, 내풍, 온도 등)을 고려하였고 지진하중은 교량의 사용수명 동안 발생 가능한 진진을 적용하였다. 이러한 신뢰도를 근간으로 각 주요부재의 취약도 점유율을 확인한 결과 받침(23.8%)이 가장 취약하였으며 받침콘크리트(20.5%), 교각(18.9%), 기초(17.3%), 보강형(14.6%), 케이블(5.0%) 순으로 나타났다.