검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study evaluated the ecotoxicological properties of livestock waste water treated by a LID (Low Impact Development) system, using a mixture of bio-reeds and bio-ceramics as suitable bed media for a subsequent treatment process of a livestock wastewater treatment plant. The relationship between the pollutant reduction rate and the ecotoxicity was analyzed with the effluents from the inlet pilot plant, with vegetated swale and wetlands and the batch type of an infiltration trench. Each pilot plant consisted of a bio process using bio-reeds and bioceramics as bed media, as well as a general process using general reeds and a bed as a control group. The results indicated that, after applying the HRT 24 hour LID method, the ecotoxicity was considerably lowered and the batch type pilot plant was shown to be effective for toxicity reduction. The LID method is expected to be effective for water quality management, considering ecotoxicity by not only as a nonpoint source pollution abatement facility but also, as a subsequent treatment process linked with a livestock manure purification facility. It is necessary to take the LID technic optimization study further to apply it as a subsequent process for livestock wastewater treatment.
        4,000원
        2.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, a low-impact development (LID) technic such as a wetland has been proposed as a Nature-friendly process for reducing pollutants caused by livestock wastewater. Therefore, the Daphnia magna toxicity was analyzed for livestock wastewater samples, to determine if a wetland system would also be effective in reducing this ecotoxicity. In the present study, acute D. magna toxicity was not significantly dependent on the presence and type of reed, nor type of media. However, when treated with construction wetlands, ecotoxicities decreased as well as TN, TP and COD concentrations. Therefore, it is considered that a construction wetland system with bio reeds and bio-media as well as general reeds would be effective to reduce the ecotoxicity of livestock wastewater. To apply a wetland system as the subsequent treatment process to a livestock waste water treatment facility, it is necessary to perform an integrated evaluation such as treatment efficiency and the ecotoxicity test for various characteristics of livestock wastewater.
        4,000원
        3.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Euglena agilis의 운동성 반응을 자동으로 측정하는 장치 인 E. agilis 시스템 (E-Tox)을 이용하여 8종의 중금속 (Ag, Cd, Cr(VI), Cu, Hg, Ni, Pb, Zn)에 대한 독성시험을 실시하 였다. E. agilis 운동성 시험 (biomonitoring test)으로부터 도 출된 EC50과 문헌상의 자료 조사로 얻은 기존 생태독성 시 험 생물 종들(D. magna, V. fischeri, 그리고 E. gracilis)의 EC50을 비교하여 시험물질에 대한 E. agilis의 독성 민감도 를 평가하였다. 또한 축산폐수 방류수, 도금폐수 방류수, 도 금폐수 1차 처리 시료에 대해 D. magna 급성 독성시험과 E. agilis 운동성 반응 시험을 수행 후 TU를 비교하여 E. agilis 운동성 시험의 현장 적용 가능성을 평가하였다. E. agilis는 시험 중금속에 대해 D. magna보다 독성민감도가 전반적으 로 낮았으나 V. fischeri 또는 E. gracilis와 유사하거나 좀 더 민감하였다. E. agilis는 D. magna test로 유독성으로 판명된 도금폐수 1차 처리수에 대해 신속한 독성반응을 나타내었 다. E-Tox 시스템은 기존의 생태독성시험장비에 비해 빠르 고 작동이 간편한 자동화 기기라는 장점이 있다. 본 연구의 결과 E-Tox 시스템을 이용한 E. agilis 운동성 시험은 향후 독성폐수에 대한 조기경보를 위한 생태독성시험법으로 적용 될 수 있을 것으로 판단된다.
        4,000원
        4.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 경기도 안산 도금폐수 처리시설에서 총 4 개 시료를 대상으로 국내 생태독성시험 표준 생물 종인 D. magna와 국내서식 종 E. agilis를 이용한 생태독성을 수행 하였다. 시료에 대한 독성원인물질 탐색은 D. magna 급성 독성시험법을 이용하여 1) 시료 내 개별 중금속 농도와 시 료의 독성영향과의 상관분석, 2) 원인물질탐색 실험 (단계적 pH, SS, 중금속, 산화제 Test), 3) 중금속 목적물질에 대한 독 성영향 농도와 시료 내 목적물질의 농도와의 비교 등을 통 해 평가하였다. 도금폐수 시료에 대한 E. agilis 시험법의 적 용 가능성 평가는 E. agilis 실시간 생태독성 모니터링장비 (E-Tox 시스템)를 이용하여 수행하였다. D. magna 시험 결 과, 시료의 독성원인물질군은 부유물질 (SS), 산화제 그리고 중금속으로 예측되었으며 개별 중금속 원인물질은 Cu, Hg, Ag로 판단되었다. E. agilis는 D. magna에 비해 독성 민감도 는 높지 않으나 D. magna에 독성영향을 나타내는 도금폐수 시료에 신속하고 민감하게 반응하였다. 본 연구의 결과 D. magna를 이용한 단계별 독성원인물질 탐색평가과정은 생 태독성기준을 초과하는 도금폐수 시료에 대한 독성 원인물 질을 파악하는데 효과적으로 나타났다. 또한 E-agilis 시험은 향후 도금폐수의 수질을 실시간으로 모니터링 하는데 적용 가능 할 것으로 판단된다.
        4,000원