        2017.04 구독 인증기관 무료, 개인회원 유료
        In case of underground construction affected by groundwater, CIP (Cast-In-Place Pile) method is generally used to resolve the geo-hydraulic problem. However, as this method has poor connectivity between piles, an auxiliary method for cut-off is needed in many cases. In this study, a new concept earth retaining wall method (H-CIP) with no auxiliary method, by using surfactant grout (Hi-FA) which improves antiwashout and infiltration ability, is introduced, and its field applicability is evaluated. CIP and H-CIP piles were installed with same ground conditions, and field permeability tests were conducted to verify the performance. As results, newly contrived H-CIP method shows higher antiwashout performance for cut-off than conventional CIP method.
        3,000원