This study developed a consecutive convexo-concave shaped shear reinforcement approach as an alternative for transverse crossties in basement walls. Test results revealed that the developed shear reinforcement is more favorable to restricting the opening of the inclined cracks and enhancing the shear capacity of the basement wall when compared with the conventional crossties.