검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2022.08 KCI 등재 서비스 종료(열람 제한)
        In order to photocatalytically treat organic matter (CODCr) and chromaticity effectively, chemical coagulation and sedimentation processes were employed as a pretreatment of the leachate produced from landfill in Jeju Island. This was performed using FeCl3・6H2O as a coagulant. For the treated leachate, UV/TiO2 and UV/TiO2/H2O2 systems were investigated, using 4 types of UV lamps, including an ozone lamp (24 W), TiO2 as a photocatalyst, and/or H2O2 as an initiator or inhibitor for photocatalytic degradation. In the chemical coagulation and sedimentation process using FeCl3・6H2O, optimum removal was achieved with an initial pH of 6, and a coagulant dosage of 2.0 g/L, culminating in the removal of 40% CODCr and 81% chromaticity. For the UV/TiO2 system utilizing an ozone lamp and 3 g/L of TiO2, the optimum condition was obtained at pH 5. However, the treated CODCr and chromaticity did not meet the emission standards (CODCr: 400 mg/L, chromaticity: 200 degrees) in a clean area. However, for a UV/TiO2/H2O2 system using 1.54 g/L of H2O2 in addition to the above optimum UV/TiO2 system, the results were 395 mg/L and 160 degrees, respectively, which were within the emission standard limits. The effect of the UV lamp on the removal of CODCr, and chromaticity of the leachate decreased in the order of ozone (24 W) lamp > 254 nm (24 W) lamp > ozone (14 W) lamp > 254 nm (14 W) lamp. Only CODCr and chromaticity treated with the ozone (24 W) lamp met the emission standards.
        2.
        2005.11 KCI 등재 서비스 종료(열람 제한)
        The treatment of styrene vapor was carried out using the biofilter packed with loess/polyurethane composite during continuous operation of 74 days. The microorganisms were adapted within 2-3 days under the experimental conditions of inlet concentration and empty bed contact time (EBCT). At 200 sec of EBCT, the removal efficiency of styrene was 100% with 200 ppmv of inlet concentration, while 92% with 400 ppmv of inlet concentration. The biofilter showed the stable removal efficiencies of over 74 % under the EBCT range from 300 to 75 sec at the 150 ppmv of inlet styrene concentration. The maximum capacity of styrene removal for the biofilter packed with loess/polyurethane was 29 g/m3/hr. During continuous operation of 74 days, pH of the drain water changed slightly and the pressure drop through the biofilter column was below 45 mmH2O/m.