검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2014.10 KCI 등재 서비스 종료(열람 제한)
        The object of this research is to find out the psychological change of observer according to the index of Greenness in the space of scenic planting, and research is proceeded with total 112, male students 69, and female students 43. The index of Greenness experimented with 5 pictures, 20%, 40%, 60%, 80%, and 100%, and carried out the test after selecting each picture of the index of Greenness for landscaping in Konkuk University Global Campus. To find out the mood condition of testee, POMS and SD was used for analyzing. As a result of TMD among POMS, male and female students are shown as each 60% > 100% > 40% > 20% > 80% in order. As a result of SD, male and female students are shown as 80% > 20% > 40% > 60% > 100% in order and the index of Greenness 100% makes people feel fluent and natural about plants but closed and constrained than the index of Greenness 80%.
        2.
        2014.08 KCI 등재 서비스 종료(열람 제한)
        This study, the urban energy used office building green roof type composition of the target by analyze building energy reductions. Green roof is total 6 types(type A~F) were selected, EnergyPlus the energy simulation programs were used. Top floor of green roof types evaluation, the reduction of the cooling peak load type E(1.26%), type D(1.30%), type C(1.37%), type B(1.45%), type F(1.49%), and heating peak load is type D(1.32%), type E(1.40%), type C(1.47%), type F(1.69%), type B(2.13%) order. Annual cooling load of heating load is reduced more than about 1% effect. The heating load reduction ratio for a maximum of 9% respectively. Cooling peak load of the building energy performance evaluation of type F >type B >type C >type D >type E in the order and in the case of peak loads heating type B >type F >type D >type E >type C order. Annual total energy use reduction of 1.07 to 1.22% and earn, type B in the best good. In primary energy use reductions in the presence of a green roof were in the 4249~4876 kWh/yr. Annual CO2 emissions reductions of unapplied type A were analyzed on average 469.78 kg.
        3.
        2014.07 KCI 등재 서비스 종료(열람 제한)
          This study suggests plan of green space management based on the result of research apprehending the characteristic through sorting types of city thermal environment targeting summer which thermal pollution is the most serious. Considering anthropogenic heat, development level of wind road, thermal environment, as a result of types of thermal environment process, it is appeared 36 types, and 10 types is relevant of this research subject. Type Ⅰ-1, size of building is large, artificial covering area is wide, and thermal load of anthropogenic heat is high, typeⅡ-1, development condition of wind road is incomplete as Ⅱlevel, entering cold air is difficult and thermal management and improvement is needed area. Type Ⅲ-1, scale is large and it is area of origin of cold air, development level of wind road is mostly favorable, type Ⅲ-2 is revealed as smaller scale than Ⅲ-1, and small area of origin of cold air. Type Ⅳ, anthropogenic heat is 81~150 W/㎡, average, but development function of wind road is very favorable. Type Ⅴ, large area of thermal load and the origin of cold air are distributed as similar ratio, and level of development function of wind road is revealed as Ⅱ level. According to standard of type classification of thermal environment, as a result of suggesting plan of green space management and biotops area ratio, type Ⅰ-1 is buffer green space and waterway creation, goal biotops area ratio 35%, type Ⅱ-1 afforestation in site and goal biotops area ratio 40%, type Ⅲ-1, preservation plan to display the current function continuously is requested. Type Ⅳ suggests afforestation of stream current, and typeⅤ suggests quantitative increase of green space and goal biotops area ratio 45%.
        4.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        This study were performed on roadside buffer green in Songpa-dong, Songpa-gu, Seoul in order to analyze the anion concentration according to the type of composition of roadside buffer green. Buffer green separating the physical structure of the measurement points and measurement locations were separated by roadside, green interior, the other side of the road. planting density and deposit of trees per each buffer green was measured in the order of mounding type> slope type> the plain type. If the measured temperature of the location-specific weather elements roadside> inside> the other side of the road in order of measurement and the temperature is lowered farther away from the road. If the relative humidity of the road on the other side> inside> the roadside in order to measure and this is the opposite of the temperature tendency. According to physical structure reduction of the temperature on the other side of the road and roadside in order of mounding type> the plain type> slope type was measured. As a result of measuring a anion therefore concentration of the anion inside of melt is in order of mounding type> the plain type> slope type, tended to match the melt characteristics. According to measured positions anion concentration is in the order of the other side of the road> inside> the roadside was measured. As a result of correlation analysis, in the case of measurement location-specific weather and anions the temperature is positive correlation, relative humidity is negative correlation and that's results of previous studies were supported.