검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2022.10 구독 인증기관·개인회원 무료
        In 2017, Kori unit 1 nuclear power plant was permanently shut down at the end of its life. Currently, Historical Site Assessment (HSA) for MARSSIM characteristics evaluation is being conducted according to the NUREG-1575 procedure, this is conducted through comprehensive details such as radiological characteristics preliminary investigation and on-site interview. Thus, the decommissioning of nuclear power plant must consider safety and economic feasibility of structures and sites. For this purpose, the establishment of optimal work plan is required which simulations in various fields. This study aims to establish procedure that can form a basis for a rational decommissioning plan using the virtual nuclear power plant model. The mapping procedure for 3D platform implementation consisted of three steps. First, scan the inside and outside of the nuclear power plant for decommissioning structure analysis, 3D modeling is performed based on the data. After that, a platform is designed to directly measure the radiation dose rate and mapped the derived to the program. Finally, mapping the radiation dose rate for each point in 3D using the radiation dose rate calculation factor according to the time change the measured value created on the 3D mapping platform. When the mapping is completed, it is possible to manage the exposure dose of workers according to the ALARA principle through the charge of radiation dose rate over time because of visualization of the color difference to the radiation dose rate at each point. For addition, the exposure dose evaluation considering the movement route and economic feasibility can be considered using developed program. As the interest in safety accidents for workers increases, the importance of minimum radiation dose and optimal work plan for workers is becoming increasingly important. Through this mapping procedure, it will be possible to contribute to the establishment of reasonable process for dismantling nuclear power plant in the future.
        2.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존의 바나듐 레독스 흐름전지(vanadium redox flow battery, VRFB)에서 사용하고 있는 과불소계이오노머인 나피 온(Nafion)은 전해질에 존재하는 바나듐 이온의 투과도가 높아, 바나듐 이온이 분리막을 투과하여 반대쪽 전해질로 교차 이동 하는 문제를 갖고 있다. VRFB에서 바나듐 이온의 투과는 서로 다른 산화수를 갖는 바나듐 이온이 부반응을 일으켜 충전, 방전 용량의 감소를 야기하고, 장기적인 성능 감소를 일으키는 원인이 된다. 이러한 문제를 해결하기 위해 본 연구에서는 SiO2에 3-aminopropyl group이 도입된 나노입자(fS)를 Nafion에 분산시켜 바나듐 이온의 투과를 감소시키고, VRFB의 장기적인 성능 의 향상을 도모하고자 하였다. SiO2에 붙어 있는 아민기(-NH2)가 Nafion의 술폰산 음이온(SO3 -)과 이온결합을 형성함과 동시 에, 암모늄 양이온(-NH3 +)의 양전하가 바나듐 이온에 대해 Gibbs-Donnan 효과를 나타내어 낼 것이라고 기대하였다. fS를 섞은 Nafion 용액의 pH와 Nafion-fS 막의 IEC 측정을 통해 암모늄 양이온과 술폰산 음이온의 이온결합이 존재하는 것을 확인하였고, fS의 양이 많아질수록 바나듐 이온의 투과도가 감소하는 것을 확인하였다. VRFB 단위 전지에 제조한 복합막을 도입하였을 때, 150 mA/cm2의 전류밀도에서 충방전 사이클을 200회 반복 진행하여도 방전용량을 최대 80%까지 유지할 수 있었다.
        4,300원