A comparative analysis of the hindered amine light stabilizers (HALS) and UV abosrber (UVA) and their respective photostabilizing effect on wood plastic composites (WPCs) are reported in this study. The influence of accelerated weathering on the mechanical properties of the composites and the microscopic morphology of a degraded layer on the cross section and the surface were studied. UV absorbers were more efficient at preventing composite lightening than was UV stabilizer. The amount of whitening decreased with the increase of photostabilizers. With the addition of a UV absorber (Tinuvin360), the tensile modulus and strength of the composites increased slightly. However, the addition of a light stabilizer (Tinuvin770) and a UV absorber decreased the tensile modulus and strength of the composites. After 250 and 500 hr exposure, tensile modulus and strength of the un stabilized and stabilized composites decreased. The tensile strength of UV absorber (Chimassorb81)-stabilized composites was significantly greater than that of control and light stabilizer (Tinuvin770)- and UV absorber (Tinuvin360)-stabilized composites. UV absorber-stabilized samples showed less whitening and photodegradation than control and light stabilizer-stabilized samples.
Cellulose nanofibers from microfibril cellulose (MFC) was prepared by hydrobromic acid (HBr) treatment at different concentrations. Polyvinyl alcohol (PVA) composite films at various loading level of nanofibers were manufactured by a film casting method. The analysis of degree of polymerization (DP), crystallinity (Xc) and molecular weight (Mw) of cellulose after acid treatment was conducted. The mechanical and thermal properties of the cellulose nanofibers reinforced PVA films were characterized using tensile tests and thermogravimetric analysis (TGA). The DP and Mw of MFC by HBr hydrolysis considerably decreased, but Xc showed no significant change. After acid hydrolysis, the diameter of cellulose nanofibers was in the range of 100 to 200 nm. The thermal stability of the films was steadily improved with the increase of nanofiber loading. There was a significant increase in the tensile strength of PVA composite films with the increase in MFC loading. Finally, 5 wt.% nanofiber loading exhibited the highest tensile strength and thermal stability of PVA composite films.
S. marcescens LSY4가 충전된 BOD센서를 제작하여 표준오염물질을 포함한 수용액의 BOD를 측정하였다. 배양시간이 9∼16시간일 때에는 배양시간에 따른 BOD센서의 감응도에 큰 차이를 나타내지 않았으며, 균체량도 0.22~0.75mg cm-2의 범위에서는 거의 동일한 센서의 감응도를 나타내었다. 수용액의 pH가 4~9사이로 변화할 경우 센서의 감응도가 가역적으로 변화하였으나 수용액이 더 산성이거나 더 염기성이 되면 센서의 감응도가
원자로 내 사고발생 시 냉각수의 비등으로 기포가 발생하고, 기포율을 측정하기 위하여 열수력 안전 분 야에서는 주로 Optical Fiber Probe(OFP)나 광학 카메라를 이용하여 측정하지만 기하학적 구조의 한계로 인 해 17 × 17 배열의 봉 다발 내에 장비를 설치하는 것에는 어려움이 있다. 본 연구는 예비 연구로서 봉 다발 에 적용하기 전 X선 시스템과 다양한 모사 팬텀을 이용하여 연구 가능성 평가를 수행하였다. 라디오그라피 및 토모그라피 실험을 통해 X선 발생 장치의 관전압 130 kVp, 관전류 1 mA가 적합하였다. 또한, 기포 해상 도 팬텀을 통해 가시적으로 1 mm 크기의 구멍에 대해 측정이 가능하였으며 막대 팬텀을 이용한 대조도 평 가의 경우 프레온 내부에서 대조도가 상대적으로 떨어짐을 확인할 수 있었다. 그러나 영상 재구성 시 일그 러짐이 없는 좋은 영상을 획득할 수 있었다. 기포 발생 팬텀 실험을 통해 기포의 유동 방향 확인 및 단층 영상을 획득할 수 있었고, Image J 툴을 이용하여 하나의 단층영상에 대해 18 %의 기포율을 측정할 수 있 었다. 본 연구는 핵연료 주변 기포율 측정을 위한 선행 연구를 수행하였고 지속적인 연구를 위한 기초 연 구로서 활용할 수 있을 것이다.