        21.
        2018.04 서비스 종료(열람 제한)
        This research is about design optimization and performance evaluation for composite PC slabs using improved horizontal shear connectors. As a result of the tests, the improved shear connectors show structural performance even when they are placed only in the required section.
        22.
        2017.09 서비스 종료(열람 제한)
        This research is about the optimization of design and application of the horizontal shear connectors for composite PC slabs. As a result of test, the improved horizontal shear connector shows a structural performance that can displace the lattice horizontal shear connector.
        24.
        2014.04 서비스 종료(열람 제한)
        This paper describes the structure performance of glass fiber-reinforced polymer (GFRP) shear connectors for insulated concrete sandwich panels (CSP). In this study, experiments are conducted to investigate the physical features of insulated CSP with GFRP shear connectors with varying shape and specification of GFRP shear connectors, and types of insulations. Test results indicate that developed GFRP shear connector has a significant effect on structure performance of insulated CSP.
        25.
        2013.10 서비스 종료(열람 제한)
        This study focuses on the push-out tests performed for verifying the performance of Y-type perfobond rib shear connectors. The end bearing resistance of the Y-type perfobond rib shear connector may be determined by the sizes of rib height and rib width. Therefore, in this study, the end bearing resistance is analyzed according to the rib widths and rib heights.
        26.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        This paper describes an experimental program to investigate the shear behavior of insulated concrete sandwich panels (CSPs) with different types of GFRP shear connector. The study included testing of 13 insulated CSP specimens with two types of surface conditions for extruded polystyrene (XPS) insulation and various shapes of shear connectors. All specimens were loaded in direct shear by means of push-out and were consist of three concrete panels, two insulation layer and four rows of GFRP shear connectors. Load-relative slip between concrete panel and insulation response of CSP specimens has been established through push-out shear test. Test results indicate that the surface condition of insulation has a significant effect on the bond strength between concrete panel and insulation. The specimen used XPS foam with 10mm deep slot shows higher bond strength than those used XPS foam with meshed surface. Corrugated GFRP shear connectors show equivalent strength to grid GFRP shear connectors. Cross-sectional area and embedded length of shear connector have a notable effect on overall response and inplane shear strength of the CSP specimens.
        27.
        2013.04 서비스 종료(열람 제한)
        In this study, thickness of FRP sheet on Connector, which did not cause any physical damage to concrete column, was decided by using nonlinear finite element analysis. Through this analysis, the optimal thickness was determined by a thickness of the Glass Fiber sheet
        28.
        2012.05 서비스 종료(열람 제한)
        This study was shear strength of insulated concrete sandwich panels with tress shear connector. Specimens with results XPSSTG insulation than the EPS insulation was good in the Shear Strength. The maximum displacement is better than the EPS specimens and that of the specimens XPSSTG trends that appear are considered.
        29.
        2011.02 서비스 종료(열람 제한)
        건축물의 단열은 효율적인 에너지 사용을 위한 필수적인 기술이다. 중단열 콘크리트 외벽 시스템은 내/외측에 두 개의 콘크리트 벽체와 중앙부 단열재로 구성되어, 단열성능과 구조성능을 동시에 만족시킬 수 있는 시스템이다. 중단열 콘크리트 외벽 시스템을 구조체에 적용하기 위해서는 콘크리트와 단열재 부착면의 전단내력에 대한 검증이 필연적으로 요구된다. 본 연구는 파형 FRP 전단연결재로 보강한 중단열 콘크리트 외벽 시스템의 전단연결재의 매립깊이, Pitch, 폭에 따른 전단내력을 평가하기 위하여 실시되었다. 실험결과 동일단면적에서 Pitch가 넓은 경우 전단내력이 소폭으로 증가하는 결과를 보였다. 매립깊이가 깊을수록 전단내력을 증가하였고, 폭 12mm 와 18mm의 경우 각 각 35, 40mm 이상의 매립깊이가 필요할 것으로 판단된다.
        30.
        2011.01 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 직접전단응력 및 휨 전단응력의 비교분석을 통하여 Perfobond Rib 전단연결재를 사용한 구조물의 하중방향에 따른 전단응력 분석이다. 직접전단응력 분석을 위해서 5개의 변수로 Perfobond Rib 전단연결재 실험체 5개를 제작하고Push-out Test를 실시하였다. 실험 후 Perfobond Rib 전단연결재의 전단저항 메커니즘을 규명하고, 직접전단응력에 영향을미치는 주요 인자를 바탕으로 직접전단력을 산출할 수 있는 제안식을 제시하였다. 또한 휨 전단응력의 분석을 위해 강-콘크리트 합성 바닥판 실험체를 제작하고 정적 휨실험을 실시하였다. 정적 휨실험을 바탕으로 휨 거동특성을 분석하고 휨 전단응력을계산하였다. 직접전단응력과 EN 1994-1-1을 통해 계산된 휨 전단응력을 비교하여 하중방향에 따른 전단저항응력에 대해서분석을 하였다.
        31.
        2007.03 KCI 등재 서비스 종료(열람 제한)
        본 연구는 조적조 치장벽체의 신축과 보강공사에 사용될 수 있는 나선형 긴결철물을 사용하여 내부벽체와 긴결된 치장벽체의 전단거동실험을 행하여 이 벽체의 구조적 성능을 검증하고 적절한 시공간격⋅형태 등을 제안하기 위한 실험연구이다. 본 연구를 통해 벽체의 Rocking거동에 있어서는 나선형 긴결철물을 사용한 벽체가 기존 시공법의 벽체보다 동일 간격에서는 우수한 전단저항능력을 나타내며, 간격이 30%정도 증가하여도 유사한 능력을 발휘한다. 짧은 간격에서의 긴결도는 기존 시공법보다 상당히 높음으로 고층건물의 치장벽체로 연와조 조적체의 적용가능성을 높일 수 있을 것으로 판단된다.
        32.
        2006.11 KCI 등재 서비스 종료(열람 제한)
        강․콘크리트 합성구조에서 강재와 콘크리트 사이의 경계면에 효과적인 응력전달과 합성거동을 유도하기 위하여 스터드, 채널, 유공강판 등이 사용된다. 가장 광범위하게 사용하는 전단연결재는 스터드 형식이고, 최근에 들어서는 강판에 구멍을 뚫은 유공강판전단연결재인 Perfobond가 주목을 받고 있다. 본 연구는 강․콘크리트 합성교량에 적용하기 위한 Perfobond형 전단연결재의 연성능력과 전단성능을 향상시킬 목적으로 횡방향 전단구속철근을 배치하고, Push-out 실험을 수행하여 전단내력을 비교하였다. 실험결과, 유공강판 전단연결재에 전단구속철근, 횡방향 관통철근, 단부 지압판 등을 설치함에 따른 수평 저항성능이나 다웰효과 등에 의해 전단내력이 상승하였으며, 또한 최대내력 이후 변형능력이 유지되면서 연성거동 특성을 보였다.