        In this study, the self test-system for the marine Gyrocompass was developed and the obtained results are summarized as follows : 1) Utilizing the newly developed self-test system, the time length for observing the transient state of Gyrocompass reading which has been over 4 hours can be reduced to less than 20 minutes. In addition, the dynamic characteristics of the Gyrocompass can be measured within 2 hours after starting the system. 2) Prior test and diagnosis was done by checking all parameters recurrently with period of 2.5minutes. 3) Testing and diagnosis results was shown in graphic mode and could be transmitted to INMARSAT unit using personal computer. 4) The results of the newly designed trouble algorithm for the system was found to be applicable under arbitrary given conditions.