        Fuel Test Loop(FTL) is a facility which could conduct a fuel irradiation test at HANARO (High-flux Advanced Neutron Application Reactor). FTL simulates commercial NPP’s operating conditions such as the pressure, temperature and neutron flux levels to conduct the irradiation and thermo- hydraulic tests. The In-Pile Test Section(IPS) installed in HANARO FTL is designed as a pressure vessel design conditions of 350℃, 17.5MPa. The instrumentation MI-cables for thermocouples, SPND and LVDT are passed through the sealing plug, which is in the pressure boundary region and is a part of instrumentation feedthrough of MI-cable. In this study, the brazing method and performance test results are introduced to the sealing plug with BNi-2 filler metal, which is selected with consideration of the compatibility for the coolant. The performance was verified through the insulation resistance test, hydrostatic test, and helium leak test.