The demand for ceramic brackets, which have a high aesthetic purpose due to their high light transmission is increasing due to the application of poly-crystalline alumina material. Brackets using this material require stable properties that should not fracture during the treatment period. In this paper, the fracture strength of a ceramic bracket made of the same material used in clinical practice was checked by applying torque with a square stainless steel wire. The wire used in the test was prepared with cross-section sizes of 017 inch ✕ 025 inch, 018 inch ✕ 025 inch, and 019 inch ✕ 025 inch. There were a total of 150 bracket specimens and after ligating wires in the slots, torque was applied to each of 75 specimens in the gingival and occlusal directions. The torque test used digital torque meter equipment and the torque value at which the bracket slot fractured due to plastic deformation of the ligated wire was confirmed. Based on the resulting data we plan to use the data to recommend stable torque use and develop future bracket design.
최근 시공의 합리화와 경제성의 목적으로 한 다양한 연구가 진행되고 있다. 철근 콘크리트 기둥과 철골 보로 이루어진 RCS 구조의 개발에 대한 연구 역시 활발해지고 있다. RCS 구조 보-기둥 접합부 패널존의 저항기구는 내부패널에서 외부패널로 응력이 전달될 때 직교보의 영향을 받지만, 기존연구에는 직교보의 영향을 고려하지 않고 있다. 본 연구에서는 웨브, 플랜지, 직교보의 두께, FBP의 유뮤등 다양한 변수들을 가지는 5개의 철근콘크리트 기둥과 철골보로 이루어진 보-기둥 내부접합부 실험체의 실험을 통해 직교보들의 영향과 구조적 성능을 조사하고자 한다. 이러한 실험결과들로부터, 보-기둥 접합부의 직교보가 전단내력과 구조성능을 향상시키는데 효과적이라는 것을 알 수 있다.