        Recently, the concept of an outrigger damper system with a damper added to the existing outrigger system has been developed and applied for dynamic response control of high-rise buildings. However, the study on the structural characteristics and design method of Outrigger damper system is in the early stages. In this study, a 50 story high - rise building was designed and an outrigger damper system with viscoelastic damper was applied for wind response control. The time history analysis was performed by using the kaimal spectrum to create an artificial wind load for a total of 1,000 seconds at 0.1 second intervals. Analysis of the top horizontal maximum displacement response and acceleration response shows that outrigger damper systems are up to 28.33% and 49.26% more effective than conventional outrigger systems, respectively. Also, it is confirmed that the increase of damping ratio of dampers is effective for dynamic response control. However, since increasing the damping capacity increases the economic burden, it is necessary to select the appropriate stiffness and damping value of the outrigger damper system.
        4,000원
        2.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In recent years, an outrigger damper system has been proposed to reduce dynamic responses of tall buildings. However, a study on outrigger damper system is still in its early stages. In this study, time history analysis was performed to investigate the dynamic response control performance of outrigger damper. To do this, a actual scale 3-dimensional tall building model with outrigger damper system has been developed. El Centro earthquake was applied as an earthquake excitation. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. Analysis results, on the top floor displacement response to the earthquake load, was greatly effected by damping value. And acceleration response greatly was effected by stiffness value of damper system. Therefore, it is necessary to select that proper stiffness and damping values of the outrigger damper system.
        4,000원
        3.
        2005.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 횡하중을 받는 아웃리거 시스템의 횡변위를 정량적으로 제어할 수 있는 효율적인 강성최적설계기법을 제시하고 이를 이용하여 아웃리거 시스템의 거동특성 및 효율성을 평가하고자 한다. 이를 위해 아웃리거를 이용한 고층 구조물의 거동특성을 고려한 민감도 해석을 수행하며 아울러 수학적계획법의 일반성을 유지하면서도, 큰 규모의 문제도 효율적으로 다룰 수 있는 근사화 개념을 도입하여 구속조건식을 설정한다. 특히 초기에 주어진 단면형상이 최적설계 과정동안 계속 유지된다는 가정을 이용하여 부재재설계 기법을 개발한다. 제시된 정량적인 횡변위 제어 방안의 효용성을 검토하기 위해 네 가지 형태의 50층 고층구조물 예제가 고려된다.
        4,000원
        4.
        2017.04 서비스 종료(열람 제한)
        In this study, it was modelled high-rise building applying outrigger damper system and analyzed by applying eccentric load. By controlling the variation of damping and stiffness of the damper, the seismic response control performance of outrigger damper system was analysed. An outrigger damper system is effective in controlling the top floor displacement response and torsional angle. Therefore, the damper should be selected the proper stiffness value because the variation of stiffness have an influence on the torsional angle.