The use of dampers is being considered a means to improve the seismic performance of buildings. It may take considerable time and effort to find an optimal design solution since repeated three-dimensional nonlinear time history analyses are required. Therefore, a preliminary design procedure for seismic retrofit using hysteretic dampers was proposed in this study. In the proposed procedure, the amount of retrofit (required number of dampers) is estimated from the capacity curve of the building before retrofit and allowable story drift of the building. In combining the capacity curves of the building and the dampers, the deformation demand for the dampers can be easily checked against their deformation capacity. The equations to transform the device displacement to roof displacement for the combination of capacity curves are developed. The proposed procedure was applied to the seismic retrofit design of sample buildings. The study found that the estimated capacity curve was very close to the actual capacity curve obtained from the pushover analysis, which can determine an appropriate configuration to meet the required seismic performance.
In this study, a design procedure for the practical application of the dampers to building structures under earthquake loads was presented by using earthquake response spectrum. Nonlinear time history results using a 10 story building structure installed with damper verified the effectiveness of the proposed procedure by showing that the structural response could be reduced to the target performance level for seismic loads. Since the proposed design procedures are based on response spectrum seismic analysis result of the original structure, the capacity, location and the number of damper and the consequent response reduction effects can be preliminarily determined without performing the nonlinear time history analysis.
Since 2003, policies and practices related to the reduction of CO2 gas emission from ships has been discussing by the International Maritime Organization. The representative emission index and indicator are the EEDI (Energy Efficiency Design Index) for the new ships and EEOI (Energy Efficiency Operational Indicator) during the voyage. In this paper a water tank test and procedure development are introduced for the purpose of improving EEDI. The results showed good agreement explaining the characteristics properly.
본 연구의 목적은 건축구조물의 지진응답제어를 위한 MR 감쇠기의 크기, 개수 및 최적위치를 결정하는 설계절차를 제안하는 것이다. 기존의 연구에서 제안된 MR 감쇠기의 모델링 방법들의 특성과 차이점을 진동제어효과의 관점에서 분석하였으며, 이 모델 중 해석이 간단하고 이력특성을 모사할 수 있는 이력 이점성 모델을 사용하여 MR 감쇠기의 변수연구를 수행하였다. 건축구조물의 층간에 설치되는MR 감쇠장치의 용량은 지진응답의 경우 구조물의 주기와 감쇠비에 따라 층전단력이 다르게 됨을 고려하여, 20개의 지진하중에 대한 해석으로부터 구한 응답스펙트럼을 이용하여 결정하였으며, 설치 갯수에 따른 제어경향을 분석하였다. MR 감쇠기의 크기, 개수, 그리고 최적위치를 결정하기 위한 방법이 제안되었으며, 기존의 점성감쇠기 설계시 이용되는 층간변위 혹은 층간속도가 가장 큰 층에 순차적으로 설치하는 방법과의 비교를 통해 유효성을 검증하였다. 수치해석결과는 제안된 방법을 사용하여 MR 감쇠기의 크기, 개수, 그리고 위치를 합리적으로 결정할 수 있음을 보여준다