검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The operating parameters considered in this study include evaporating and condensing temperature, degree of subcooling and degree of superheating. in R744-R717 cascade refrigeration system and R744 two-stage compression refrigeration system with the range of low temperature -50℃∼-30℃. The coefficient of performance(COP) of R744-R717 cascade refrigeration system is about 16∼20% greater than that of R744 two-stage compression refrigeration system in the range of evaporation temperature of -50℃∼-30℃. R744 two-stage compression refrigeration system is unstable because its coefficient of performance changes significantly depending on the evaporating temperature and total compression work, and compression efficiency decreases. In this case, not efficient for long-term use. Whereas R744-R717 R744-R717 is a cascade refrigeration system using eco-friendly refrigerants. And this system is a high-efficiency refrigeration system that performs well even under various operating conditions. This is why it can be configured by selecting a refrigerant suitable for the high temperature side and the low temperature side.
        4,000원
        2.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using Natural refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative natural refrigerant R290(Propane), R600(Butane), R717(Ammonia), R1270(Propylene) for freon refrigerant R22 were used working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative nreon refrigerants have an effect on COP of this system.
        4,000원
        3.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system using alternative Freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Pure alternative Freon refrigerant R32, R134a and near NARM(Non-Azeotropic Refrigerants Mixtures) R404A, R407C, R410A and ARM(Azeotropic Refrigerant Mixtures) R507A were used working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter- cooler of two-stage compression and one-stage expansion refrigeration system using alternative Freon refrigerants have an effect on COP of this system.
        4,000원