검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2025.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pipe organs are an important element of acoustic performance and usage of concert hall, considered as one of indicators of classical music hall. However, only limited numbers are installed or planned for local concert halls. Therefore, in order to investigate the influence of the pipe organ to the concert hall and compare with variable acoustic equipment, acoustic parameters were measured and evaluated in conditions without the pipe organ and after installation. Moreover, acoustic parameters according to acoustic variable equipment were measured and evaluated to figure out an impact on acoustic performance. The result indicates that differences of parameters according to the presence of the pipe organ were, 0.66 sec in reverberation time (RT), 0.1 in bass ratio (BR), 0.66 sec in early decay time(EDT), 2.18dB in clarity (C80), 0.12dB in strength(G), and 0.16 in lateral energy fraction(LFC). Differences of acoustic parameters due to acoustic variable equipment were 0.86 sec in reverberation time(RT), 0.09 in bass ratio(BR), 0.78 sec in early decay time(EDT), 0.64dB in clarity(C80) and 2.34dB in strength(G).
        4,000원
        2.
        2011.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        In accordance with increase of the leisure time due to the recent economical development of the people, since the interest on the cultural performance becomes high, the construction of various performance hall is on increasing in domestic. However, in case of the multi-purpose hall constructed in domestic, because the various genres performances are performed in the one space without any special variable equipment, those of many problems have been raised that unable to satisfy the acoustic capability suitable to the purpose of performance. In case of the performance place such as the multipurpose hall, it is the requiring real situation that the variable typed system-equipped performance hall which able to adjust the acoustic characteristics suitable to each performances. Accordingly, this study has ever predicted the optimized acoustic performance through computer simulation before-opening the hall, also has ever evaluated the acoustic performance through the actual survey after-opening the hall. It is considered that such study result could be utilized as the most useful material when construction the similar multipurpose hall equipped with the variable typed system, hereafter.
        4,300원