        2025.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pipe organs are an important element of acoustic performance and usage of concert hall, considered as one of indicators of classical music hall. However, only limited numbers are installed or planned for local concert halls. Therefore, in order to investigate the influence of the pipe organ to the concert hall and compare with variable acoustic equipment, acoustic parameters were measured and evaluated in conditions without the pipe organ and after installation. Moreover, acoustic parameters according to acoustic variable equipment were measured and evaluated to figure out an impact on acoustic performance. The result indicates that differences of parameters according to the presence of the pipe organ were, 0.66 sec in reverberation time (RT), 0.1 in bass ratio (BR), 0.66 sec in early decay time(EDT), 2.18dB in clarity (C80), 0.12dB in strength(G), and 0.16 in lateral energy fraction(LFC). Differences of acoustic parameters due to acoustic variable equipment were 0.86 sec in reverberation time(RT), 0.09 in bass ratio(BR), 0.78 sec in early decay time(EDT), 0.64dB in clarity(C80) and 2.34dB in strength(G).
        4,000원