In order to analyze the pressure drop of the fluid passing through the hydraulic coupler, a flow model using the Computational Fluid Dynamics (CFD) analysis technique was developed and the fluid flow rate and pressure distribution inside the coupler were analyzed. The analysis model was corrected by comparing the pressure drop measurement using a 6.35mm hydraulic coupler with the ISO reference value and the simulation prediction value. Using the calibrated model, the flow rate and pressure drop of 13 types of hydraulic couplers distributed on the market were analyzed, and their performance was determined by comparing them with ISO reference values. In the case of type A coupler, the pressure drop was generally higher than the ISO reference value, and in the case of type B coupler, the pressure drop was similar to or lower than the ISO reference value. It was confirmed that the complex flow analysis inside the hydraulic coupler could be easily performed through computational fluid dynamics (CFD) modeling, and based on this, problems could be identified and performance could be improved performance.
The objectives of this study were to develop the optimal structures of recirculating aquaculture tank for improving the removal efficiency of solid materials and maintaining water quality conditions. Flow analysis was performed using the CFD (computational fluid dynamics) method to understand the hydrodynamic characteristics of the circular tank according to the angle of inclination in the tank bottom (0°, 1.5° and 3°), circulating water inflow method (underwater, horizontal nozzle, vertical nozzle and combination nozzle) and the number of inlets. As the angle in tank bottom increased, the vortex inside the tank decreased, resulting in a constant flow. In the case of the vertical nozzle type, the eddy flow in the tank was greatly improved. The vertical nozzle type showed excellent flow such as constant flow velocity distribution and uniform streamline. The combination nozzle type also showed an internal spiral flow, but the vortex reduction effect was less than the vertical nozzle type. As the number of inlets in the tank increased, problems such as speed reduction were compensated, resulting in uniform fluid flow.
산업현장과 열병합발전 등 다양한 장소에 사용되는 도시가스는 산업안전보건법 정의에 따라 인화성 가스에 해당되며 한국산업표준 KS C IEC에 의해 가스 폭발위험장소가 설정되어 안전하게 관리가 되어야 한다. 본 연구에서는 일반 화학공장에 적용되는 KS C IEC 표준을 저압 도시가스 사용설비 폭발위험성 예측에 합리적으로 적용하기 위해누출공 크기, 환기 등급, 환기 유효성 등의 주요 변수를 도입하였다.CFD 시뮬레이션 적용의 타당성을 평가하기 위해 전산유체역학 (CFD) 시뮬레이션, 가스누출실험, KS C IEC 표준 계산 통해 얻어진 폭발하한계가상 체적을 이용하여 네 가지 다른 조건에서 폭발 위험성을 평가하였다.
세계적으로 급증하는 전력수요에대처하고, CO2 배출을 줄이고자 인구가 밀집되어 있는 도 심지에 복합화력 발전소가 건설되고 있다. 환경규제가 계속적으로 강화됨에 따라 NOx 배출량을 줄이고 자 저 NOx 버너, SCR 등 여러 가지 설비들을 설치하고 있다.
본 연구는 경기도 고양시 소재의 일산열병합발전소 1개소에서 배출되는 질소산화물을 TMS를 이용하 여 배출계수를 산정하여 이를 전산유체동역학(CFD)에 적용하여 질소산화물의 거동을 살펴보고, 현장 실 측 결과와 비교 검토하였다.
실측 기간 중 측정 시간에 따른 주 풍향․풍속의 순간적인 변화로 인해 실측 결과와 CFD 모델링 결과 의 차이가 나타날 수 있으나, 모델링 결과와 실측 결과는 대부분 예측지점에서 유사한 농도로 나타났다. 향후 주변농도를 고려한 기여농도를 산출하여 실측농도에 가까운 예측농도 도출이 가능 할 것으로 판단 된다.
소각로 내 공기 주입은 연소가스의 체류시간, 미연분 제거 및 출구가스 온도 제어 등의 많은 영향을 끼친다. 이에 따라 2차 연소용 공기량을 변화시켜 충분한 체류시간을 확보하고 850℃ 이상의 출구가스 온도를 유지하며, 높은 turbulent를 관리함으로써 안정적인 소각로 운영이 되어야만 한다. 본 연구에서는 현재 운영 중인 소각장의 소각로를 설계하고, 평균 일일 소각량을 바탕으로 1차 공기량을 산정한 후 2차 공기량을 변화하여 CFD 프로그램(Fluent)을 통해 이론적인 공기유동을 규명하였다. 또한 산정된 공기량을 바탕으로 실제 운영 중인 소각장에 적용함으로써 최적의 연소조건을 도출하였다. CFD simulation 결과 1.2차 공기비는 75:25가 최적의 결과로 나타났으며, 2차 공기 분사노즐 전 후면 유속 비는 1:3에서 가장 우수한 결과로 나타났다. 또한, 실제 운영 중인 소각로에 적용한 결과 적절한 소각로 출구온도는 질소산화물 제거 효율 및 일산화탄소 발생농도에 영향을 미치는 것으로 나타났다.