The safety at this study is investigated by flow or stress analyses due to configuration or installation direction of fuel tank in the existing CNG bus. In case of the lower ceiling with sharp type, the equivalent stress due to the explosion of fuel tank is less than the type of flat or arc. it becomes safer on passenger. In case of the installation direction of fuel tank in the existing CNG bus, the stress applied on the lower ceiling at transverse direction becomes less than at longitudinal direction. It is more stable on the safety of passenger. The harm on the explosion accident can be prevented by use of the analysis result at this study.