검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the performances of H2S, NH3, and HCl sensors for real-time monitoring in small emission facilities (4, 5 grades in Korea) were evaluated at high concentration conditions of those gases. And the proper approach for the collection of reliable measurement data by sensors was suggested through finding out the effect on sensor performances according to changes in temperature and humidity (relative humidity, RH) settings. In addition, an assessment on sensor data correction considering the effects produced by environmental settings was conducted. The effects were tested in four different conditions of temperature and humidity. The sensor performances (reproducibility, precision, lower detection limit (LDL), and linearity) were good for all three sensors. The intercept (ADC0) values for all three sensors were good for the changes of temperature and humidity conditions. The variation in the slope value of the NH3 sensor showed the highest value, and this was followed by the HCl, H2S sensors. The results of this study can be helpful for data collection by enabling the more reliable and precise measurements of concentrations measured by sensors.
        4,000원
        2.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        식물의 생장과 발달은 지하부 환경에도 영향을 받으므로 근 권 환경의 변수들을 관수전략의 수립에 고려하는 것이 매우 중요하다. 본 연구의 목적은 수분이동 특성이 다른 2종류의 암 면배지에서 FDR센서를 활용하여 체적함수율(VWC)과 Bulk EC(ECb) 그리고 식물의 뿌리가 이용하는 Pore EC(ECp)에 대한 관계를 분석하고, 이를 활용하여 이용가능한 근권 환경 데이터 수집과 보정 방법을 확립하고자 진행되었다. 실험은 물리적 특성이 다른 2종류의 암면배지(RW1, RW2)를 사용 하였다. FDR 센서를 활용하여 함수율(MC)과 ECb를 측정하 였으며, ECp는 체적함수율(VWC) 10-100%에서 배지 중 앙부위에 일회용 주사기를 이용하여 배지 잔류 양액을 추출 후 측정하였다. 이후 2종류 배지(RW1, RW2)에 서로 다른 농 도(증류수, 0.5-5.0)의 배양액을 각 체적함수율 범위(0- 100%)로 공급하여 ECb와 ECp를 측정하였다. RW1, RW2 배지에서 ECb와 ECp의 관계는 3차 다항식에 가장 적합하였 다. 체적함수율(VWC) 범위 3차 다항식에 따른 ECb와 ECp 의 관계는 낮은 체적함수율(VWC) 10-60% 구간에서 큰 오 차율을 보였다. 체적함수율(VWC)범위에 따른 센서 측정값 (ECb) 및 식물 뿌리가 이용하는(ECp)의 상관관계는 2종류 배 지(RW1, RW2) 모두 Paraboloid 식에서 결정계수값이 각각 0.936, 0.947로 가장 높았다.
        4,000원
        3.
        2018.04 구독 인증기관·개인회원 무료
        In recent decades, introduction of the alien plant pests into Korea was dramatically increased and the role of plant quarantine became more important than ever. At the same time, early detection of the introduced population of the alien pests is critical for protection of their spread. However, continuous monitoring for their distribution or spread has not been performed yet in Korea. Present monitoring systems in Korea is not unified but sectored according to three institutes. There are some limitations in managing human resources, executing budgets, and collecting information among them, resuling in delayed responses to the introduced alien pests. Our study focused on 1) constructing nation-wide continuous monitoring system, 2) developing a decision flow chart for evaluating risks, 3) performing the benefits and costs analysis. Continuous monitoring will clarify overall distribution of alien pests, support government’s quarantine negotiation, and enable early detection of alien pests. Furthermore, the system will provide scientific data management and early responses to invasion of alien pests.
        4.
        2012.12 KCI 등재 서비스 종료(열람 제한)
        The ion selective microelectrodes (ISME) have been applied to observe the continuous profiles of NO3-N and NH4-N in bulk solutions or biofilms. In order to evaluate the performance and applicability of ion concentration measuring system, the characteristics, such as slope of calibration curve, detection limit and potentiometric selectivity coefficient were investigated. The slopes of calibration curve showed high degree of correspondence for each target ion concentrations. And the detection limits of nitrate and ammonia ion selective microelectrode were 10-4.7 M and 10-4.4 M, respectively. These ion selective microelectrodes were proved that their own performance could be maintained for 16 days after making. NO3-N and NH4-N selective microelectrodes were also adapted to detect the continuous ion profiles of cilia media packed MLE (Modified Ludzack-Ettinger) process. And the monitored nitrate and ammonia ion profiles with the ion selective microelectrode were stable and well corresponded to the results with conventional ion chromatograph. However, the electric potential was unstable until 8 hr because of the unknown noise. The tip shape and performance of the ion selective microelectrode was stably kept over 2 days continuous monitoring.