검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, numerical analysis was performed for the purpose of analyzing the flow characteristics and performance according to the change in the inflow hydrogen temperature and differential pressure of the receptacle of the hydrogen charging system. The pressure distribution and turbulent kinetic energy in the filter area were analyzed by changing the outlet pressure condition under the inlet hydrogen temperature condition, and the flow velocity change at the outlet was compared and analyzed. As a result of the analysis, as the differential pressure decreased, the flow rate at the outlet of the receptacle decreased by up to about 70% at the 2.86 MPa condition compared to the 1.86 MPa condition, and the mass flow rate decreased by about 56.5% at the maximum. It was found that the standard CV performance was not satisfied when the differential pressure at the inlet and outlet was 1.12 MPa or less under the 363K temperature condition.
        4,000원
        2.
        2023.05 구독 인증기관·개인회원 무료
        Level measurement of liquid radwaste is essential for inventory management of treatment system. Among various methods, level measurement based on differential pressure has many advantages. First, it is possible to measure the liquid level of the system regardless of liquid type. Second, as the instrument doesn’t need to be installed near the tank, there is no need to contact the tank when managing it. Therefore, workers’ radiation dose from the system can be decreased. Finally, although it depends on the accuracy, the price of the instrument is relatively low. With these advantages, in general, liquid radwaste level in a tank is measured using differential pressure in the treatment system. Not only the advantages described above, there are some disadvantages. As the liquid in the system is waste, it is not pure but has some suspended materials. These materials can be accumulated in tanks and pipes where the liquids move to come into direct contact with pneumatic pipes that are essential in differential pressure instruments. As a result, in case of a treatment using heat source, the accumulated materials may become sludge causing interference in pneumatic pipes. And this can change the pressure which also affects the level measured. In conclusion, in case of liquid storage tanks in which the situation cannot be checked, the proficiency of an operator becomes important.
        3.
        2022.10 구독 인증기관·개인회원 무료
        There are various types of level gauging method such as using float, differential pressure, hypersonic, displacement and so on. In this study, among them, the method utilizing the differential pressure was reviewed. The strengths include: the differential pressure type level gauge can measure the level without direct contact of the sensor with media. That is to say, the level can be measured even if the sensor is far away from the tank. And regardless of the size of the tank, the level can be measured if the pneumatic pipes are installed. The weaknesses include: the sensor needs intermedium to recognize the level. The intermedium utilizes a fluid, which is compressed air. It is difficult to handle that compressed air has the properties of a gas. And to make compressed air needs compressor, tank and pneumatic pipes. So if you have many tanks, you need to install exponentially the pneumatic pipes. As well, level measurement range is limited to the points where the pneumatic pipes of the tank is installed. And if a compressed air that supplies to the sensor leaks, uncertainty will increase. A compressed air is colorless and odorless, so it’s difficult to pinpoint the leak. Finally, events like cracks and clogging can cause inaccurate measurement. Rather than using only differential pressure, it is better to use another measurement method according to the situation of the facility.