검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2018.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        One of engineered woods, glued laminated timber (GLT), can provide a constant level of performance and desired strength even if the quality of wood is low. Due to this fact, there is a growing interest in GLT using domestic species and related research has been carried out continuously. In addition, GLT is popularly being applied to the long-span or high-rise structures overseas. However, KBC 2016 does not allow the engineered woods to be used for middle and high-rise buildings by limiting height. Therefore, a proper design procedure and rationale should be clearly presented by the help of performance-based seismic design. With this background, the goal of this study is to establish a specific procedure for design of a 9-story building with RC shear walls and GLT frames according to the performance-based design of KBC 2016. The performance objectives were set according to KBC and the acceptance criteria for each goal were defined. The RC shear walls and GLT frames were designed by concrete and wood structure requirements, respectively. Analytical models were developed to reflect their nonlinear features, and both nonlinear static and dynamic analyses were conducted. Performance evaluation results showed that the shear walls have insufficient shear strength, so they were re-designed. Consequently, it has been confirmed that GLT frames can be applied to a 9-story office building with the assistance of RC shear walls and performance-based seismic design.
        4,000원
        2.
        2017.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The need for eco-friendly building materials such as engineered wood has increased to reduce carbon emissions. Although the range and height of engineered wood buildings are gradually increasing in North America and Europe, engineered wood is mainly used for low-rise residential buildings in Korea. In order to reduce carbon emissions more, therefore, it needs to expand the use of engineered wood by applying it to various buildings with different uses or more stories. With this background, the aim of this study is to investigate the applicability of engineered wood for 9-story office buildings. Since a 9-story building with engineered wood only is not allowed in KBC, an example building has RC ordinary shear walls as the lateral force resisting system while engineered wood is only used for gravity load resisting moment frames. Another example building is also used for comparison where both lateral and gravity load resisting systems are designed by RC. The applicability of engineered wood is investigated by comparing the seismic performance and the amount of carbon emission of both buildings. The result shows that the seismic performance of both buildings was not significantly different while the amount of carbon emission of the engineered wood building was much less then the RC building. Based on this result, engineered wood is sufficiently applicable to 9-story office buildings even though it still needs to pay attention to the shear design of reinforce concrete walls.
        4,000원