검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        This study Analyzed four of seven runoffs which had happened in 2012 in comparison with the runoffs shown in Kalesto data, using the fixed surface image velocimetry (FSIV) installed at Oedo stream, Jeju Island. As a result of identifying a runoff curve graph, it was analyzed that the flood runoffs calculated with two observation devices were almost equivalent. As the differences in peak flows were 10 m3/s, 0.7 m3/s and 3 m3/s, the very similar result values were calculated. Even though there were errors in RMSE(Root Mean Square Error) made by two observation devices according to the degree of the peak flow, the values of R² by flood event were 0.89, 0.87, 0.86 and 0.82, showing the result values almost close to 1. Therefore, there was a very high correlation in flood runoffs calculated with two observation devices. This research method was considered to be a very suitable method to measure unexpected flood runoffs which could happen in the island area such as Jeju island during bad weather.
        2.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        표면영상유속계(SIV)는 영상 분석 기법을 이용하여 하천의 표면유속을 측정하고, 이를 토대로 유량을 산정하는 시스템이다. 본 연구에서는 고정식 표면영상유속계(FSIV) 시스템을 달천 수전교에 설치하여 실시간으로 연속적인 유량 측정을 실시하였다. 수전교에 적용된 FSIV의 하드웨어 시스템은 영상 획득을 위한 2대의 디지털 카메라와 컴퓨터, 그리고 수위 측정을 위한 초음파 수위계로 구성된다. 이 현장 장비들에서 획득된 실시간 영상과 수위 자료는 무선인터넷을