The vegetated porous pavement can be installed as an alternative way to replace the traditional pavement, which contributes less to the water circulation system in the urban area. This study aims to an investigation based on the shadow and pressure of the vehicle system, where the turfgrass get grown and the green block get constructed on the grassy parking lot. This study might achieve these conclusions, in the case of use ‘green block’ makes grass parking lot, plant a kind of ‘zenith’ and takes sod thickness 40 mm are more efficient for turfgrass growth in the early times. In the case of parking over 8 hours in a day, after 5 weeks turfgrass growth would come into reduce. So over 4 hours parking and after 9 weeks, we need consider to setting up green block in grassy parking lot. The grassy ground would get pressured by the vehicles’ load and it would bring into some damage due to the load after 3 weeks. So we should put the grass’s growth root point under the designed a top of ‘green block’ level. When the vehicle amounts and parking density is in a low level, it could be an environmentally friendly product.