It is very important that the confinement of a spent fuel storage systems is maintained because if the confinement is damaged, the gaseous radioactive material inside the storage cask can leak out and have a radiological impact on the surrounding public. For this reason, leakage rate tests using helium are required for certificate of compliance (CoC) and fabrication inspections of spent fuel storage cask. For transport cask, the allowable leakage rate can be calculated according to the standardized scenario presented by the IAEA. However, for storage cask, the allowable leakage rate is determined by the canister, facility, and site specific information, so it is difficult to establish a standardized leakage rate criterion. Therefore, this study aims to establish a system that can derive system-specific leakage test criteria that can be used for leakage test of actual storage systems. First, the variables that can affect the allowable leakage rate for normal and accident conditions were derived. Unlike transportation systems, for storage systems, the dose from the shielding analysis and the dose from the confinement analysis are summed up to determine whether the dose standard is satisfied, and even the dose from the existing nuclear facilities is summed up during normal operation condition. For this reason, the target dose is used as an input variable when calculating the allowable leakage rate for the storage system. In addition, the main variables are the distance from the boundary of the exclusive area, the number of cask, the inventory of nuclide material in the cask, the free volume, and the internal and external pressure. Utilizing domestic and US NRC guidelines, we derived basic recommended values for the selected variables. The GASPARII computer code that can evaluate the dose to the public under normal operating conditions was utilized. Using the above variables, the allowable leakage rate is calculated and converted to the allowable criteria for helium leakage rate test. The developed system was used to calculate the allowable leakage rate for normal and accident conditions for a hypothetical storage system. The leakage rate criteria calculation system developed in this study can be useful for CoC and fabrication inspections of storage systems in the future, and a GUI-based program will be built for user convenience.
A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.
유리 표면에 방사성동위원소 14C를 고착시키고 문지름 시험을 통해 시험용지별 전이 인자와 표면 형상을 관찰하여 방사성동위원소 누설 점검을 위한 건식 및 습식 문지름 시험법을 연구하였다. 건식 문지름 시험법은 티슈 용지가 종이 필터를 대체 가능할 정도로 2배 높은 전이 인자를 보였고, 습식 문지름 시험법은 종이 필터 용지가 티슈 용지에 비하여 3배 높은 전이 인자를 보였다. 일반적으로 누설 점검을 위해 종이 필터를 사용하고 있지만 건식 문지름 시험법에서 티슈 용지가 대안이 될 수 있음을 보였다.