Many reinforced concrete (RC) buildings constructed prior to 1980's lack important features guaranteeing ductile response under earthquake excitation. Structural components in such buildings, especially columns, do not satisfy the reinforcement details demanded by current seismic design codes. Columns with deficient reinforcement details may suffer significant damage when subjected to cyclic lateral loads. They can also experience rapid lateral strength degradation induced by shear failure. The objective of this study is to accurately simulate the load-deformation response of RC columns experiencing shear failure. In order to do so, model parameters are calibrated to the load-deformation response of 40 RC column specimens failed in shear. Multivariate stepwise regression analyses are conducted to develop the relationship between the model parameters and physical parameters of RC column specimens. It is shown that the proposed predictive equations successfully estimated the model parameters of RC column specimens with great accuracy. The proposed equations also showed better accuracy than the existing ones.
우리나라에서는 도시 개발사업을 위한 환경영향평가를 실시하는데 있어 개발 전․중․ 후의 강우유출량을 분석하도록 규정하고 있다. 도시개발에 따른 수문학적 변화를 분석하고 대책을 수립하기 위해 수문모델이 사용되고 있으나 대부분의 경우 현장의 자료가 충분하지 않은 관계로 그 산정결 과의 신뢰도가 문제될 수 있다. 본 연구에서는 대전의 관평천 일부유역에서 2015년 7월 부터 2016년 7월 까지 자동 모니터링 장치을 이용하고 또 한 및 현장 측정을 통해 확보된 강우량 및 유출유량의 연속자료를 활용하여 SWMM을 이용하는 경우 강우 유출량 예측의 정확도를 제고하고자 하 였다. 토양침투량 산정을 위해 대표적으로 사용되는 Curve Number 방법, Horton 방법 및 Green-Ampt 방법들을 사용한 경우에 대해서 투수지 역과 불투수 지역에 대해 각각 최적의 Manning 조도계수와 지표면 저류깊이를 산정하여 제시하였다. 본 연구의 결과는 우리나라의 도시 유역에 서 실측자료를 이용하여 강우 유출 모델을 보정하였다는 면에서 의미가 있다고 판단되며 추후 유역의 개발등의 상황에 대해는 강우 시 유출량 및 수질현상을 더욱 정확하게 예측하고 나아가서 향후의 유역 내 수문조건 변화 요인에 대한 영향을 분석하는 데 정확도를 향상시킬 수 있을 것으로 기대된다.
The objective of this study is analysis of Andong-Dam lake water quality with water quality model. Model parameters of the WASP applied to Lake Andong-Dam were estimated.
The methodology is based on grouping water quality constituents and relevant parameters and successively estimating parameters by a trial-and-error procedure. Water quality system for modeling consisted of BOD, DO, T-N, T-P. The results of water quality modelling using WASP. T-N was maximum affected by K71C(Organic nitrogen mineralization rate) parameter. T-P was maximum affected by K83C(Dissolved organic phosphorus mineralization) parameter, and It did not show a difference almost from the parameter of others and it omitted. BOD was maximum affected by Temperature parameter, it was visible of the reaction due to the KDC(Deoxygenation rate) in afterwords, and It did not show a difference from the parameter of others and it omitted. DO was maximum affect by Temperature parameter, and It did not show a difference almost from the parameter of others and it omitted.
The parameter which it presumes from the this study uses a water quality modeling and Actual value and the result with which it compares, error rate the parameter presumption which is appropriate with 1% interior and exterior is investigated,
It will reach and it uses and it will be able to apply to the suitable parameter in water quality modelling of the objective area which can be feeded by it becomes.